Abstract
Twisted string actuators (TSAs) have exhibited great promise in robotic applications by generating high translational force with low input torque. To further facilitate their robotic applications, it is strongly desirable but challenging to enhance their consistent strain generation while maintaining compliance. Existing studies predominantly considered overtwisting and coiling after the regular twisting stage to be undesirable—nonuniform and unpredictable knots, entanglements, and coils formed to create an unstable and failure-prone structure. Overtwisting would work well for TSAs when uniform coils can be consistently formed. In this study, we realize uniform and consistent coil formation in overtwisted TSAs, which greatly increases their strain. Furthermore, we investigate methods for enabling uniform coil formation upon overtwisting the strings in a TSA and present a procedure to systematically “train” the strings. To the authors' best knowledge, this is the first study to experimentally investigate overtwisting for TSAs with different stiffnesses and realize consistent uniform coil formation. Ultrahigh molecular-weight polyethylene strings form the stiff TSAs, whereas compliant TSAs are realized with stretchable and conductive supercoiled polymer strings. The strain, force, velocity, and torque of each overtwisted TSA were studied. Overtwisting and coiling resulted in ∼70% strain in stiff TSAs and ∼60% strain in compliant TSAs. This is more than twice the strain achieved through regular twisting. Finally, the overtwisted TSA was successfully demonstrated in a robotic bicep.
Introduction
The twisted string actuator (TSA) is an artificial muscle consisting of two or more strings connected to an electric motor on one end and a load on the other end.1–3 As shown in Figure 1a, b, actuation is realized by twisting the strings with a motor to linearly displace a load.1–3 TSAs typically generate strains of ∼30–35% of their untwisted length with high energy efficiency.2,3 Most commonly used soft actuators and artificial muscles exhibit one or more evident limitations such as (1) fabrication complexity,4,5 (2) high power requirement,6,7 (3) slow actuation,8,9 and (4) insufficient force generation.9–11

The
For example, dielectric elastomer actuators (DEAs) and hydraulically amplified self-healing electrostatic (HASEL) actuators, while generating sufficient actuation, require complicated and high-cost fabrication procedures that could be potentially challenging to realize.5,7 DEAs and HASEL actuators also require high-voltage equipment (producing over 10 kV). This is not only costly but also potentially dangerous. Similarly, although pneumatic actuators exhibit appreciable strain and force generation, adopting them in robotic devices requires pumps or compressors.12,13 Furthermore, the thermal actuation of shape-memory alloys not only results in low bandwidth and low energy efficiency but also could be dangerous and cause damage to the robotic devices in which they are used.8,14
TSAs could present unique advantages over other actuation mechanisms. These advantages are, in part, due to TSAs' simplicity in fabrication and assembly, low power requirement, high operating frequency, large linear strain generation, and compactness. 1 Furthermore, using stretchable and conductive strings, compliance and self-sensing properties could also be obtained.15,16 TSAs have been used in tensegrity robots, robotic gloves, robotic hands, robotic exoskeletons, and other applications. 1
The important performance metrics of a TSA are the contraction range, contraction speed, force output, torque input, bandwidth, and compliance. By utilizing a suitable pair of motor and strings, a TSA can be constructed to satisfy a given force output, bandwidth, and compliance requirement. 1 However, one area that is independent of the components of a TSA and needs further improvement is the strain generation (relative to the initial string length). Compliance is essential in areas where safe interaction with human beings is demanded. Previous work used elastic strings in a TSA-driven robotic joint, 17 whereas other work used elastic supercoiled polymer (SCP) strings in TSAs.15,16
The inclusion of SCP strings in TSAs has the major advantage of resistance based self-sensing behavior.15,16 SCP strings have attracted much attention because they are compliant, lightweight, elastic, and often electrically conductive.18–21 The electrical resistance in SCP strings has been found to vary according to the strings' elastic deformation. 22 In sensing of the TSA, it is desirable to estimate its strain based on an electrical signal of the actuator. Unlike many other soft actuators, TSAs are unique in that the actuator only consists of two or more strings connected to a motor with no constraints on the type or material of strings. Therefore, replacing the typically adopted strings with conductive SCP strings could enable self-sensing TSAs.
However, the inclusion of SCP strings resulted in less strain compared to stiff strings: stiff string-based TSAs generate strain of up to 30–35% strain of their initial length, whereas SCP-based TSAs produce strains of around 20% of their initial length.15,16 Although compliance and self-sensing are desirable, large strain generation is equally critical. Heating the SCP strings could result in additional strain of ∼15% after they are fully twisted (making the total output strain around 35%), 15 but self-sensing while heating the strings has not been sufficiently studied because the electrical resistance is likely coupled with temperature, making the self-sensing behavior significantly difficult to characterize and model. Due to these reasons, the need for an alternative actuation mechanism which increases the strain output of the SCP-based TSAs, while not affecting their self-sensing capabilities, is strongly desirable.
In past studies, larger strains were obtained by “overtwisting” the strings—twisting beyond the regular twisting stage (Fig. 1c). In a study by Tavakoli et al., 23 with a two-string configuration, up to 72% strains were obtained by overtwisting strings at loads between 2 and 5 kg. 23 Although Tavakoli et al., 23 claimed overtwisting to be advantageous, existing studies predominantly considered overtwisting to be undesirable.24–28 This could be due to (1) increased nonlinearity and (2) the formation of nonuniform and unpredictable knots, entanglements, and coils in the overtwisted strings.24,27,28 In the study by Tavakoli et al., 23 although large strains were generated using overtwisting, the formation of coils was considered to be undesirable: they were neither uniform nor consistent.6,8,17,18
While the increased nonlinearity could be handled using advanced modeling techniques, the unpredictable nonuniform coil formation is most detrimental and undesirable. First, the nonuniform coil formation accelerates the actuator's failure and causes unpredictable behaviors. Second, nonuniform coils occupy more space in the direction perpendicular to the actuation direction relative to uniform coils. This could result in unwanted interaction of the strings with other system components. 23 In the meantime, TSAs in general have attracted much attention in the robotics community, resulting in increased usage to power multiple advanced robotic and mechatronic devices.27–30 It is thus strongly desirable to develop novel TSAs with increased strains.
In our work we present a novel actuation mechanism which enables TSAs to generate very high strains predictably and repeatably. By applying the proposed actuation mechanism, uniform coil formation was obtained. Furthermore, we present a procedure to systematically “train” the strings to ensure that they achieve uniform coil formation. Our experiments confirmed that both stiff and compliant TSAs can achieve uniform coils at a wide range of loading conditions. The main contributions of this article are:
Proposal of overtwisting and coiling in TSAs to greatly increase their consistent strain. The proposed method is experimentally validated on TSAs with different diameters, stiffnesses, and applied loads. Investigation of methods to enable TSAs to achieve repeatable uniform coil formation at large range of loading conditions. Comprehensive experimental characterization of the behavior of the proposed mode of actuation, and its demonstration in a standard robotic device.
To our best knowledge, this is the first study to experimentally investigate overtwisting for TSAs with different stiffnesses and realize consistent uniform coil formation. For stiff TSAs, ultrahigh molecular-weight polyethylene (UHMWPE) strings with different diameters were studied. Compliant TSAs refer to those fabricated from SCP strings and thus will be used interchangeably throughout the article. Through overtwisting and coiling, strains of up to 72% were obtained in stiff TSAs, whereas strains of up to 69% were achieved in compliant TSAs.
Materials and Methods
Proposed mode of actuation
The proposed mode of actuation consists of two phases of twisting: the regular twisting phase and overtwisting phase. In the regular twisting phase,2,3 the two strings were twisted together such that they formed a tightly packed double helical structure. 31 In the overtwisting phase, the tightly packed double helical structure then twisted to coil like single (thicker) string. Uniform coils formed along its length, resulting in the formation of a tightly packed helical structure. 31 It is noted that the proposed method is based on uniform coil formation upon overtwisting. The transition of the strings from a fully twisted state to the overtwisting state and an example of nonuniform coils are presented in Figure 2.

Training of stiff TSAs
Experiments demonstrated that TSAs with unused SCP strings consistently produced uniform coils during overtwisting, but TSAs with unused stiff strings did not. Initially it was found that uniform coil formation in TSAs with stiff strings could be obtained only at sufficiently high loading conditions. This observation was consistent with previous studies on coil formation in artificial muscles.32,33 However, uniform coil formation at lower loads—and thus a wider loading range—is desirable. Upon further investigation, the strings were found to exhibit repeatable and uniform coil formation through sufficient “training” at low loads. Although this type of training process is common for other smart materials, this procedure has never been reported for TSAs.
The training procedure consisted of the following steps: First, based on the strings' diameter, a physically feasible minimum load that ensured the strings to be sufficiently taut was chosen. “Sufficiently taut” is a condition where, after fully twisted in the normal twisting phase, the strings can return to their initial state upon untwisting without requiring any additional external force besides the applied payload. In this study, it is assumed that if a particular load ensured that the strings were sufficiently taut during the normal twisting phase, then the load would also ensure sufficient tautness for the overtwisting phase. Second, at this load, the strings underwent twisting and untwisting cycles until uniform coils formed. Fifty cycles were often sufficient to train the TSA with stiff strings to generate uniform coils during overtwisting.
As an example, the evolution of coil structure is shown in Figure 3, for the TSA with 1-mm UHMWPE strings under 200-g load. This evolution is described as follows: In the first stage, the coiling took place in the direction perpendicular to the linear actuation (Fig. 3a). In the second stage, some coils were formed along the length of the strings and remaining coils projected in the perpendicular direction (Fig. 3b). In the third stage, the coil formation started taking place along the length of the strings; however, the coils' diameters were uneven (Fig. 3c, d). In the final stage, uniform coils formed in line with the strings of the TSA (Fig. 3e). This procedure caused mild softening and gradual deformation of the strings into a helical shape.

The evolution of the coiling structure of 1-mm UHMWPE strings during training. The coiling structure of the TSA during the
Although this deformation caused a slight decrease of the TSA's operating length, it enabled the strings in each TSA to consistently form uniform coils. Since the strings in TSAs were trained at the physically feasible minimum load, they were able to form uniform coils at higher loads as well. The training process is critical for stiff strings as it enabled them to achieve uniform coil formation upon overtwisting and consequently enabled stiff TSAs to attain high strains at wide ranges of loads. More details on the training process can be found in the S1.4. Training of Stiff TSAs section is shown in Supplementary Data.
Uniformity of coils
In this article, for stiff strings, uniformity of coils implied homogeneity of the coils. Homogeneity of coils suggests that all the coils have approximately the same size and shape. Although regularity of the coils is also an important criterion, it was relaxed because during training of stiff strings, it was observed that while most coils were regular, there were few coils which formed at slightly irregular intervals (Fig. 3e). TSAs with compliant SCP strings did not require training to achieve uniform coil formation. This is likely due to their low stiffness and their supercoiled structure. However, even in SCP strings, while homogeneity of coils was observed, some coils formed with irregular spacing between them, similar to stiff strings.
Performance metrics
In this work, the strain S of the TSA is defined to be negative when the TSA's length decreased, whereas the contraction C is the negative of the strain. The strain is expressed as
where L is the current length of the TSA, and L0 is the initial loaded length. For stiff TSAs,
Results
Stiff TSAs
The TSA with 1.0, 1.3, and 2.0 mm UHMWPE strings, which were loaded with 2000, 2900, and 3400 g, respectively, was used to experimentally study multiple properties of the overtwisting actuation mode. Beyond these loads, the TSAs were likely to fail or the motor was likely to stall.
First, the strain generation was characterized for the stiff TSAs. The input sequence applied to the TSA is presented in Figure 4a, and the corresponding strain of the stiff TSA with 1.3-mm diameter strings is presented in Figure 4b, c. The motor angle–strain relationship was mildly hysteretic, but the hysteresis was negligible in the regular twisting phase. This could be because of the strings' high stiffness and load. Similar trends were found for other stiff TSAs. In all cases, around 70% contraction was observed consistently (Fig. 4b, c; Supplementary Fig. S4).

Experimental results for the stiff TSAs.
Second, the actuation velocity of stiff TSAs was obtained. The actuation velocity of the stiff TSA with 1.3-mm strings was calculated from the strain–motor rotation correlation in Figure 4b, and the velocity is presented in Figure 4d. For all the stiff TSAs, the actuation speed was significantly greater in the overtwisting phase than in the regular twisting phase. This implies that the bandwidth of the TSA's strain is greater during overtwisting than during normal twisting. More details on the bandwidth can be found in the S2.4. Discussions section is shown in Supplementary Data.
Third, the motor torque of the stiff TSAs was studied. This torque was computed by multiplying the current of the DC motor by the motor torque constant. The results of stiff TSA with 1.3-mm diameter strings are presented in Figure 4e. The results indicated that overtwisting in stiff TSAs required more torque than the regular twisting phase.
A summary of the maximum contractions, actuation speeds, and required torques of different stiff TSAs is presented in Figure 4f, g, and h, respectively. Numerical results are also presented in Table 1. Full results are found in Supplementary Figures S5–S7 and Supplementary Video S1. Results are also presented for TSAs made from Kevlar strings in Supplementary Figure S8 and Supplementary Video S2.
Comparison of Overtwisted Twisted String Actuators with Stiff Strings
Finally, a test of the TSA's lifetime was conducted (Fig. 4i). A TSA with 1.3-mm diameter UHMWPE strings under 2900-g of load was used. The motor rotated with 5-rotation steps and a 200-ms pause between each rotation. The TSA lasted for 1030 cycles without breaking. The TSA consistently achieved ∼60% contraction. Although the overall length of the TSA slightly decreased over time, the linear actuation range remained approximately constant between all cycles. The strings also gradually deformed into a helical shape. Consequently, the length of the TSA decreased, as verified by the creep-like behavior in Figure 4i. As the experiment ran, the number of coils that formed along the length of the strings also increased. Furthermore, while the generated strain changed initially due to the decrease in length of the strings, after ∼2 h from the beginning of the test, the strain did not further increase and was consistent.
Compliant TSAs
As an example, the strain and self-sensing of 6-ply SCP-based TSA under a 200-g load are considered. As shown in Figure 5a, b, the TSA repeatably achieved 11.25% strain in the regular twisting phase, then an additional 46.89% in the overtwisting phase. The relationship between twists and strain distinctly revealed the regular twisting and overtwisting phases of the TSA, as shown in the two hysteresis loops in Figure 5b. Compliant TSAs demonstrated greater hysteresis than the stiff TSAs in both the normal twisting and overtwisting phases, mainly due to the friction and material properties of SCP strings. Because the TSA was fabricated from conductive SCP strings, the electrical resistance of the strings was measured. Transient decays in the electrical resistance were observed (Fig. 5c), similar to transient resistance behaviors in other materials.34,35 The results suggest a correlation between the strain and resistance of the TSAs, which could be used for strain self-sensing. The resistance experienced mild creep as time increased, which was likely due to the friction between the strings that rubbed the silver coating off of them. 16

The experimental results for the compliant SCP-based TSAs. The data presented in
A summary of the maximum repeatable contractions for the compliant SCP-based TSAs is shown in Figure 5d. Full results are provided in Supplementary Figures S9 and S10 and Supplementary Video S3. The strains achieved by SCP-based TSAs in regular twisting phase were less than those achieved by stiff TSAs mainly because the SCP strings are compliant and stretchable. 15 Increased loads generally decreased the maximum attainable contraction (Fig. 5d). Furthermore, as the load increased, the contraction obtained through regular twisting increased but the contraction obtained through overtwisting decreased.
The lifetime endurance was also examined in the compliant TSA. Two tests were conducted with different pairs of 6-ply SCPs loaded with 100-g. On the first test, the TSA lasted for 285 cycles with consistent 60% contractions but broke on the 286th cycle (Fig. 5e). On the second test, the TSA lasted for 428 cycles and achieved consistent contractions of 45% (Fig. 5f). For both tests, the resistance demonstrated creep over time. This could be due to the friction between the strings that rubbed the silver coating off them. The TSA in the second test achieved less contraction and less resistance change because the maximum twisting angle was smaller.
Discussions
The proposed mode of actuation significantly improves the strain generation of TSAs and increases their impact in the field of robotics, more specifically in applications demanding high force and compact actuators, such as robotic exoskeletons,36,37 tendon-driven robotic fingers and arms, 28 and other robotic structures.38,39 Large strains generated through overtwisting and coiling could result in the realization of compact solutions in areas that demand large displacements. For example, consider a robotic device like the one presented in Hosseini et al., 37 which requires displacements of 10 mm. To meet this requirement, if only regular twisting is used (with up to 30% contraction), then a TSA with a length of ∼33 mm would be required. However, with overtwisting and coiling (with up to 70% contraction), a TSA with a length of only 14.3 mm would be sufficient. This would effectively reduce the untwisted strings of the TSA to less than half of their original length.
Even in the overtwisted phase, the twisted strings only mildly increased in diameter, which still allows the actuator to be conveniently placed in conduit or a sheath for wearable and assistive devices.40,41 For example, a TSA made from two 6-ply SCP strings and loaded with 200 g hanging weight had a diameter of 2.1 mm in the regular twisting phase and only 3.6 mm in the overtwisting phase. The uniformly coiled strings can also be put into bending actuators, 42 and then can be further incorporated into different robotic applications. Furthermore, soft robotic structures, such as soft bending fingers, 10 could be realized using compliant, overtwisted, and uniformly coiled TSAs. Such devices would be able to generate larger forces and quicker actuation while maintaining compliance and compactness.
Some evident limitations of the proposed mode of actuation are as follows: First, the uniform coil formation, while enabling a stable and repeatable behavior, resulted in jerky motion due to formation of coils. Although the coils were uniform, every time a new coil was formed, the string would intermittently contract at a faster rate. This may generate unwanted oscillations of the payload attached to the string.
Second, the proposed overtwisting mechanism increased the nonlinearity of the actuator. Hysteresis in TSAs and particularly compliant TSAs made with SCP strings has been recently studied in our previous work.15,16 Our previous study on self-sensing SCP-based TSAs showed that the length-resistance correlation is not only hysteretic but also contains creep and transient decay. 16 While the hysteresis in compliant TSAs is significant, stiff strings have relatively less hysteresis. This may be due to the high stiffness of the strings. Furthermore, previous studies indicate that even in the regular twisting phase, TSAs exhibit hysteresis. 3 In addition it was observed that the hysteresis in the overtwisting phase became less significant with increasing payload. This was observed in both stiff and compliant TSAs. Overall, few studies have been conducted to study the hysteresis properties of TSAs, including the characterization, modeling, and control.
Hysteresis is an extensively studied nonlinearity in the robotics and mechatronics community. To capture hysteresis, both physics-based methods and phenomenology-based approaches, such as the Preisach operator, Prandtl–Ishlinskii model, and Bouc–Wen model, have been proposed.11,43–46 Furthermore, different control schemes like feedforward control, proportional–integral–derivative control, robust control, and adaptive control have been realized.47–50 In addition, the actuator also exhibited creep-like behavior as can be inferred from Figure 5i. Previous studies on TSAs with regular twisting have hinted creep-like behavior which was observed in the current study as well. 51 Creep is a common nonlinearity found in many artificial muscles and smart materials, which does not make the actuator unstable if treated appropriately. Like hysteresis, creep has been extensively modeled in previous work.52,53 Those models could apply to overtwisting as well.
Finally, compliant TSAs exhibited low lifetimes in comparison to stiff TSAs. This is mainly due to the inherent limitations of SCP strings: The coiled structure of the SCP strings resulted in increased frictional forces between the strings when twisted and coiled. Consequently, the wear and tear of the strings increased which led to their early failure. Meanwhile, the self-sensing realized using conductive strings is an important concept because of the compact sensing achieved through it. The lifetime of complaint self-sensing TSAs can be potentially enhanced using robust stretchable conductive strings.
Robotic demonstration
Overtwisting and coiling of TSAs have great potential in robotic exoskeletons,36,37 assistive devices,40,41,54 tendon-driven robotic fingers and manipulators,28,55–57 and other robotic structures.38,39,58 In this article, a TSA-driven robotic bicep demonstrated the effectiveness of overtwisted TSAs. The 1.3-mm UHMWPE strings were used. The device was selected to demonstrate the effectiveness of the proposed mode of actuation because it has been used by other similar works5,11 to demonstrate the capabilities of novel soft actuators and artificial muscles. Furthermore, the robotic bicep is different from the weight-lifting setup used for experimental characterization because the tension force experienced by the strings changes as the bicep angle changes. This application therefore shows the enhanced strain and force outputs of the overtwisted TSAs simultaneously.
The robot was constructed using three metallic rods. The first rod (the stationary link, labeled as the upper arm in Fig. 6a) was suspended vertically from a metallic frame. The other two rods were assembled parallel to each other and formed the movable link, labeled as the forearm in Figure 6a. One end of the forearm was attached to the bottom of the upper arm by a revolute joint. The free end of the forearm was loaded with 700 g. A potentiometer at the joint measured the bending angle relative to the initial position of the forearm (Fig. 6a). The TSA was installed with the motor attached to the upper arm and the bottom of the strings attached to the forearm.

The initial angle was
Conclusion and Future Work
In this study, the overtwisting and coiling of stiff and compliant TSAs were experimentally investigated. In both cases, large strains of more than twice the strains achieved by regular twisting were obtained. The findings were further supported by the actuation speed, force generation, and required torque of the TSAs. The consistent electrical resistance measurements indicated that the overtwisted compliant TSAs have strong potential to be utilized for strain self-sensing.
Future work will overcome the limitations of the overtwisting phase. The first limitation is that the number of twists must be precisely monitored to achieve maximum strain without breaking the TSA. The second limitation is that the friction experienced by the coils during overtwisting wears the silver coating off from the nylon threads at a higher rate (than during normal twisting), thereby affecting their self-sensing behavior. In future work, first, a physics-based model of overtwisting and coiling of the TSA will be developed. Consequently, closed-loop position control will be realized. Second, high-endurance self-sensing could be realized in stiff and compliant TSAs by coating the strings with high-performance conductive material, similar to work by Piao and Suk. 59
Footnotes
Acknowledgments
Authors' Contributions
J.Z. conceived the idea. R.K. and D.B. conducted experiments and analysis. All authors wrote the article.
Author Disclosure Statement
No competing financial interests exist.
Funding Information
This work was supported, in part, by a NASA Space Technology Graduate Research Opportunities award (grant number: 80NSSC21K1282).
References
Supplementary Material
Please find the following supplemental material available below.
For Open Access articles published under a Creative Commons License, all supplemental material carries the same license as the article it is associated with.
For non-Open Access articles published, all supplemental material carries a non-exclusive license, and permission requests for re-use of supplemental material or any part of supplemental material shall be sent directly to the copyright owner as specified in the copyright notice associated with the article.
