Abstract
Introduction
Over the last decade, many studies on continuous monitoring of activities of daily living (ADL) of elderly people have been carried out. The main themes of the studies were health-smart homes, aging in-place, or simple activity telemonitoring. Telemonitoring ADL could improve elder care by enhancing a sense of safety and quality of life, by detecting key events (such as loss of autonomy, disease onset, and falls) and by enabling timely intervention. Moreover, long-term monitoring can also allow professionals to make informed decisions, to monitor deterioration in chronic illnesses, or to assess response to a treatment.
Changes in daily activity level (or daily habits) can provide important clues regarding functional capability, cognitive abilities, loss of autonomy/independence, deterioration in health status, or progress of an existing illness. 1 For example, people with depression tend to move less, putting weight on may limit activity level, and vice versa, a patient with chronic heart failure may be less likely to move as his or her condition deteriorates, or an elderly person with influenza may tend to spend more time in bed. An elderly person who is unable to perform ADL such as preparing a meal, eating, bathing, or climbing the stairs or exhibits poor medication adherence is more likely to suffer from a rapid deterioration of quality of life and health status and more likely to fall. 2,3
The relationship between mobility and health status is well recognized. Increased mobility improves physiological and psychological well-being and quality of life, may prevent rapid deterioration of health status of chronically ill people, 4 and improves muscles and bones 5 (i.e., makes you become less prone to bone fractures after a fall).
Although there are significant numbers of systematic reviews and meta-analysis on telemonitoring of chronic diseases, with themes of technology or treatment effectiveness, 6 –14 there are only a few reviews on ADL telemonitoring. 15,16 Telemonitoring technologies were classified into ambient sensor technologies, wearable technologies, and combinational technologies. 15 ADL monitoring was reviewed under four categories: activity, sleep, falls, and gait/posture monitoring.
The small number of reviews may be due to the fact that the studies were mainly demonstrations and/or evaluations of a new technology/approach rather than a clinical trial investigating effectiveness of the technology. Furthermore, they lack a common evaluation framework.
The objective of this review was to identify and summarize ADL telemonitoring of the elderly, determine areas that require further investigation, identify issues that need to be taken into account (including user perceptions), and review the effects of ADL telemonitoring systems on telecare of the elderly. We believe that the findings may provide useful points for the design and development of future systems and studies.
Materials and Methods
The following databases were queried for studies in English: PubMed, Scopus, and IEEE. A combination of three sets of search terms (Table 1) was sought in the title, abstract, and key words/MeSH terms. The first set of terms was relevant to ADL monitoring, the second set of terms to telemetry or telemedicine, and the third set to the subject age group. A separate search was carried out for user perception, using the additional set of search terms relevant to user satisfaction. Between January 1, 1995 and June 30, 2011, 256 abstracts were retrieved. Duplicate search results were eliminated, leaving 175 unique studies for abstract review.
Search Terms and Strategy Used (Last Updated July 2011)
Selection Criteria
Only peer-reviewed publications were included. Studies that were designed to monitor ADL of the elderly, that used telemetry for transmitting relevant parameters/data, and that assessed acceptability of such monitoring systems by the users were included.
Exclusion Criteria
Studies that were not in English, studies without an abstract, studies that could not be located, studies that classified only body movements or postural transitions, studies that aimed to promote physical activity among young people or monitor athletes' performance and assist them in training activities articles, studies that assessed the effect of body movements on physiological measurements, review articles, and studies that did not present significant outcomes were excluded. Studies that used telephone calls 17 or videoconferencing to obtain relevant data were excluded. Studies that used plain sound or video signals as the main tool for ADL monitoring were also excluded 18,19 because these methods are known to raise privacy issues.
The authors independently retrieved the abstracts and assessed these based on the inclusion criteria. This resulted in 67 studies for full text review (Fig. 1). Seven further studies previously identified were included. The selected articles were reviewed independently by each researcher, and those that did not meet the selection criteria were excluded. Reference lists of the retained publications were hand-searched for further publications that might be relevant and assessed for inclusion using the criteria. Three further studies were determined from the review process. Twenty-five studies were finally included in the review.

Study selection process.
Results
From the selected articles (Fig. 1), we extracted data on the following items: 1. Study characteristics, including number of subjects, subject characteristics, laboratory or home environment, follow-up duration, and study type 2. Monitoring device and telemonitoring characteristics, including any user interaction required, decision support capability, emergency detection capability, approaches for proactive treatment, level of support (education, regular contacts, reminders), and alarms 3. Monitored parameters (e.g., ADL, body movements, physiological data) and sensor characteristics 4. Outcomes: relation between changes in habit data and health status, sensitivity and/or specificity for predicting events requiring intervention or fall detection, rates of false alarms, user perception of such monitoring systems, effectiveness of the intervention, and technical problems experienced
We placed the selected studies into three main groups according to the parameters that were monitored:
We consider the selected studies in three aspects: 1. Study characteristics 2. Parameters monitored and sensors used 3. Outcomes
The element on the parameters that were monitored was further categorized into the type of measurement: activity measurements, physiological data measurements, and self-rated symptoms. The element on outcomes was divided into alarms, user perception, and relating the activity data to well-being.
Tables 2 –4 list the details of the studies that met the inclusion criteria, including the characteristics of the subjects, follow-up duration, parameters monitored, sensors, and outcomes for Groups 1–3, respectively. Those studies that had a small number of subjects and short follow-up duration or only undertook the validation of a device are not presented in Tables 2 and 3. The studies that used workshops and focus groups or surveys to determine user preferences are not presented in Table 4.
Summary of Characteristics and Results of Studies That Monitored Activity Data Only
BP, blood pressure; CAR, circadian activity rhythm; CVA, cerebrovascular accident; FU, follow-up; IR, infrared; NI, no information; PIR, passive infrared; SD, standard deviation; TA, tri-axial accelerometer.
Summary of Characteristics and Results of Studies That Monitored Activity and Physiological Data
ADL, activities of daily living; BP, blood pressure; CHF, congestive heart failure; FU, follow-up; HR, heart rate; NI, no information; PIR, passive infrared; PR, pulse rate; QoL, quality of life; W, weight.
Summary of Characteristics and Results of Studies on User Perception
CCTV, closed circuit TV; FU, follow-up; SF-36, Short Form 36 health survey to evaluate a person's health and ability to do everyday activities.
Study Characteristics
Certain feasibility studies were included as they were among the first attempts on activity telemonitoring for the elderly. 20,21 The former reported the preparation phase of a three-phase project; the latter described a system for assessing the ability to live alone/independently.
The purpose and evaluation methods of the studies reviewed varied significantly (Tables 2 and 3). Some focused on validation of a system or platform, 22 –24,28,31,35,37,39 some had as their aim the detection of changes in behavioral pattern, 26,29,30 and others investigated physiological measurements and self-rated symptoms in order to better predict subjects' well-being. 32,33,38 Some studies had more specific aims: monitoring nighttime activities of subjects with cognitive disabilities, 25 monitoring restlessness after surgery, 27 measuring functional capacity of cardiac rehabilitation patients, 34 and predicting key medical events. 36
Two of five studies on user perception detailed the experience of participants with involved actual telecare technologies 40 or smart home technologies. 41 The other three studies used workshops and focus groups 42,43 or questionnaires 44 to elicit user perception.
The number of subjects included in studies in Group 1 was low (Table 2). 22 –25,27 –30 The studies in Group 2 tendeded to have more subjects, and all but one 39 used more than 20 (Table 3). The studies on user perception of activity telemonitoring systems used 13–30 subjects 40 –43 (Table 4) but would be considered statistically insufficient. The questionnaire survey for acquiring symptoms 44 was performed on 477 subjects.
Studies attempting to associate activity data with physiological data or aim to evaluate user perception tend to use subjects only from a highly targeted group. This includes almost all studies in Group 3, 21,25 –27,29,30,32,34,36,38,39 and it would be difficult to generalize findings to other populations. Those evaluating accuracy of a device used volunteers 24,31,35,37 and so are self-selecting and again would preclude generalization of results.
Follow-up durations varied significantly from minutes 24,31,35 to years. 27,29,36,38,40,41 Studies evaluating a new wearable device tended to have shorter follow-up durations, whereas studies evaluating ambient sensors and aiming to relate activity patterns to health status tended to have longer follow-up durations.
Activity Measurements
Most of the studies monitoring ADL addressed loss of autonomy or well-being. The indicators of loss of autonomy included difficulties in performing ADL (e.g., meal preparation, personal hygiene, bathing, and dressing) without help from a caregiver, deterioration in cognitive abilities (e.g., forgetting to turn off electrical appliances, poor medication adherence), or pathological behavior linked to cognitive impairments. 1
Indicators of well-being/general health status included mobility, frequency of bathroom visits, sleep patterns, in-bed restlessness, level of nocturnal activities, medication adherence, meal preparation activities, and falls. For example, persistent increase in nocturnal activity and irregular eating patterns may be linked to declining cognitive abilities or onset of dementia. 30,45,46 Too much time spent in a particular room can be related to depression, fatigue, an illness, or a possible fall. Likewise, there are links between insufficient sleep and increased risk of fall, forgetfulness, or irregular behavior. 46
Interviews with over 40 expert practitioners and discussions with elderly people indicated four ADL to be important to monitor: medication adherence; up-and-around transference; bathroom use; and meal preparation. 22 Relative importance placed on activities varied depending on the practitioner. On the other hand, the elderly themselves placed the greatest emphasis on those activities that gave them a sense of empowerment and helped them to remain independent.
The method of acquiring activity data varied (Tables 2 and 3) and included passive infrared (PIR) motion sensors, 25,27,29,30,32,33,38 electricity consumed by lights and appliances, 28 radiofrequency identification technology, 24 accelerometer-based devices, 23,31,34,35 a pedometer, 37 and a self-rated mobility questionnaire. 36 Some of the studies used a compact, wearable device with activity sensor and medical/physiological sensors, 31,35 and some used only ambient sensors. 22,25,28 –30,32,33,36,40,41 Ambient sensors were used in some studies to better distinguish activities (e.g., PIR motion and door sensors) 35 or door sensors on the refrigerator door and silverware drawers to detect meal preparation 22,41 or on the wardrobe to detect dressing activities. 21
Table 5 identifies the sensors used for ADL monitoring. The most popular sensors, in order of popularity, were PIR sensors, accelerometers, chair sensors, bed sensors, medication adherence sensors, and door sensors. In some instances, use of some sensors was discontinued because of discomfort or unreliability or additional hazards introduced by the sensor itself, for example, unreliable floor mats to avoid hazards of tripping, 38 malfunctioning chair sensors, 38 bed sensors, 39 and electrocardiogram leads and electrodes. 34
Sensors Used for Monitoring Activities of Daily Living
PIR, passive infrared; RFID, radio frequency identification.
Wearable activity sensors were mainly used to monitor or differentiate activities related to body movements or metabolic energy expenditure. Activities detected varied depending on the position of the sensor. Waist-worn accelerometers were used to detect falls, classify body movement (standing, sitting, lying, and walking), estimate metabolic energy expenditure, monitor functional balance, and/or investigate whether estimated energy expenditure was related to self-reported health. 23,34 A wrist-worn unit could only differentiate simple body movements such as walking, running, resting, immobility, or dangerous fall 31 and could manage sleep/awake classification. 37 An ear-worn accelerometer based unit 35 could classify activities into four groupings: very low-, low-, mid-, and high-level activities.
Some of the studies attempted to detect falls in addition to other ADL. 21,23,31,32,34,38 The general approach for fall detection was to use an accelerometer- or gyroscope-based wearable device and use a threshold-based approach. 23,31,34,47 –49
Other methods to detect falls included floor vibration sensors, 38,50 gait characteristics, 51 sound source height information gathered through an array of acoustic sensors, 52 and background-subtracted silhouette imagery. 38 A “possible fall” was suspected by detecting inactivity for 45 min following a bed exit. 32 The common problem with fall detectors was the high rate of false alerts (i.e., low specificity).
Physiological Data Measurements
The most common physiological parameters measured were blood pressure, heart/pulse rate, respiratory flow/rate, and weight (Table 6). Other measurements included saturation of peripheral O2, electrocardiography, 31,34 and HR variability. 34,37 Some studies measured the heart and respiratory flow rate through the bed sensor and used these parameters to support activity monitoring. 32,33,38,39
Summary of Physiological Data Measurements
Obtained through the bed sensor.
BP, blood pressure; BTB HV, beat-to-beat heart rate variability; ECG, electrocardiography; HR, heart rate; PR, pulse rate; SpO2, saturation of peripheral O2.
Self-Rated Symptoms
Self-rated symptoms involved questionnaires and/or wellness diaries, either paper 23,39 or with a monitoring device. 36,37 Some studies attempted to determine whether sensor data could provide independent measures for health status. For this purpose, symptoms were correlated with variables from sensor data (e.g,, weekly self-reported health status with energy expenditure information calculated from accelerometer data 23 or self-reported sleep times with the bed sensor data 39 ). Symptoms were directly used for generating alerts. 36
A wide range of self-rated symptoms was used with elderly congestive heart failure patients. 36 These included angina, shortness of breath, swollen ankles, bloated stomach, dizziness, cough, urine excretion, eating well, medication taken, and need for an extra pillow. Symptoms relevant to stress, sleep, exercise, and sickness 37 and those relevant to sleep quality, daily activities, pain, and rehabilitation program activities 39 were collected. Weekly health status was obtained 23 through the COOP/WONCA health questionnaire, 53 which comprises 5-point charts in six domains: physical fitness, feelings, daily activities, social activities, overall health, and change in health status.
Only a small percentage of alerts were key events. 36 Symptoms such as swollen ankles, urine excretion, need for an extra pillow at night, and cough were most often correct in predicting a key event. On the other hand, diet was the least accurate indicator of a key event. Personalized and optimized thresholds were suggested in order to reduce false alert rates.
Outcomes
Only one study considered the impact of passive health status monitoring technology on cost of care and efficiency of professional caregivers. The average number of hospital visits, hospital days, and cost per subject for assisted living subjects were less than those for usual-care subjects. 33
Relating Activity Data to Physiological Data and Well-Being
Some studies 21,23,25 –30,32,33,36,38 attempted to relate activity level to well-being or health status. For example, excessive bathroom visits and increase in restlessness during the night were related to rectal bleeding or urinary tract infection, 32 pain from osteoarthritis, 33 and surgery. 27 Likewise, the number of times the elderly opened/closed their wardrobe/drawers was related to their dressing ability, 21 weekly self-reported health status to energy expenditure calculated from accelerometer data, 23 in-bed restlessness to increased bedroom activities, 25 persistent increase in nocturnal activity to declining cognitive abilities or onset of dementia, 28,30 and heart rate variability at night to sleep quality. 34 Tiredness of a congestive heart failure patient was associated with sleeping in the chair during the night. 32
Alarms
Some monitoring systems had emergency detection capabilities, including cessation of activity, 20,25 falls, 21,23,31 –34 high pulse and low pulse, 32,33 and forgotten stove burner. 32,33 Fifteen types of alarms were noted, 36 pertaining to physiological measurements, medication adherence, diet, and symptoms. Some systems were able to provide reminders for particular activities (e.g., lock doors, take medication on time, and turn off appliances). 22
Few methods were used for detecting changes in activity pattern, but included (1) comparing two sequences of activities, 30 (2) relative increase or decrease, 27,28,32 –34,38 and (3) detecting deviations from a statistically identified normal pattern. 25,26,29,30 The normal pattern was usually defined as the interval of mean±2 SD or mean±3 SD, where SD is the standard deviation.
User Perception
Two of 11 studies in Group 1 and 5 of 9 studies in Group 2 presented results on user perception of monitoring systems. The results were concerned with comfort of a wearable device, 23,31,34,37 comfort of bed sensor, 39 reliability, 31 ease of use, 23,37 obtrusiveness at home, 28,37 and visual aspects. 31 Detailed results on various aspects of user acceptability are reported. 23,28,38
Preferences differed between an elderly and a working age group. 37 For example, none of the elderly thought that the monitoring system was disturbing at home compared with 29% of the working age group (Table 3).
All preferred an assistive technology rather than one that took away their sense of control and confidence or was constantly reminding/telling them what to do. 42 Simple, quick installation and no maintenance were among the preferred features for systems. 42 One participant said that interaction with the system should be as simple as “push a button.” 43
There were concerns regarding ownership of the data, 22,38,41,42 who has access to the data, and “who decides what to monitor.” 25,42 Healthcare providers and close family members were the desired recipients of the data.
Discussion
This review summarizes the characteristics, outcomes, and limitations of 25 studies on telemonitoring ADL of the elderly. Almost all of the studies observed some benefits in the use of telemonitoring for changes in the ADL. However, it was not possible to combine studies in a meta-analysis because of heterogeneity of parameters, outcomes, and methodological approaches. Nevertheless, the outcomes of the studies provide important guidance on an optimum or improved strategy for future trials.
This is the first review on the potential benefits of ADL monitoring on the elderly and identifies a significant gap in research in the field: whether monitoring ADL and physiological data together could improve management of elderly people's care and health. This question requires larger, long-term studies with clinically relevant outcomes and common methodology.
In the following parts we discuss the findings of the study characteristics, parameters to monitor, preferred sensor and system characteristics, and recommendations on these for future research.
Study Characteristics
Although some studies monitored activities for a period of 6 months or longer, the need for even longer evaluation periods is advocated. 30 Studies should develop tools or a knowledge base for decision support by analyzing data retrospectively. Studies should use subjects selected on objective metrics from real target groups (i.e., elderly people or the chronically ill) with longer follow-up durations. 37 Development and evaluation studies should follow common methodology and ideally be based on randomized controlled trials, with carefully selected relevant outcome measures, in order to assess the actual benefits of using such systems compared with conventional care.
Parameters Monitored and Sensors Used
Activity measurements
Important home ADL to monitor include dressing, self-hygiene, toilet use, meal preparation, medication management, communication ability, functional mobility (up-and-around transference, move in bed, stand, bending, etc.), and home management (house cleaning, laundry, finances). 1 Some may not need continuous monitoring (e.g., communication ability, bending, dressing) because periodic evaluation or temporary monitoring may suffice. Continuous monitoring would be appropriate for the following: toilet use, meal preparation, medication management, up-and-around transference, movements in bed, chair use, and falls.
Sensors used were mainly environmental, except for accelerometers and some physiological sensors. Ambient sensors could not differentiate the subject from visitors, as opposed to wearable activity sensors. Noise and artifacts due to body motions reduced clinical accuracy of physiological data from wearable sensors and their ability to distinguish body movements. 31,34,35 Wearable activity detectors could only distinguish simple activities (e.g., walking, running, resting, fall, or total lack of movement 31 ) or simple classes like very low-, low-, mid-, or high-level activities. 35 These activity classes did not provide information about the capability of the subject for independent living (e.g., meal preparation, performing self-hygiene, or frequency bathroom visits). There were also issues including discomfort, and sensors were not worn during certain activities (e.g., shower or in bed). 25,30,31,34,35 The wearable sensors were thought to be unsuitable for cognitively impaired patients as the sensors are likely to be forgotten or thrown away. 25,30 Therefore, ADL monitoring requires use of a combination of ambient sensors (i.e., PIR, medication dispenser, door sensors).
Researchers have tried to extract further information from PIR data. 29 Using only person in room sensors it was possible to monitor habits and deviations from normal behavior pattern and so infer bathroom use, sleep quality, in-bed restlessness, wandering, and meal activity and provide alerts for timely intervention. PIR sensors are less intrusive than worn sensors, and owing to an added security feature they are highly accepted by elderly. 40,41 However, without user identification, they cannot differentiate multiple residents or residents from visitors. Therefore, in their current form, they are most suitable for people living alone. Activity data when visitors were present were considered to be too noisy for accurate analysis. 28,29 Such noisy intervals can be excluded from the data if they can be detected (e.g., through increased activity rate when visitors are present as suggested by Franco et al. 28 ). For future large-scale deployment purposes, a radiofrequency user identification feature can be added to such ambient sensors.
Additional sensors can be used, and outputs from these can be combined with PIR data in order to obtain more accurate information about the activity being performed. This would include sensors to detect use of specific objects such as bed, chair, door, kettle, and TV 21,22,25,30 and electronic medication dispensers. 22
There are no clear indications of the usefulness of some of the activity sensors (e.g., video sensors, sound sensors, and pressure mats other than crude presence detection). 20,38 Computational complexity inherent in video signal processing is an issue. 54 Video and sound also present issues around privacy for use in places such as bedroom and bathroom—two important rooms for fall detection 55 and ADL monitoring.
User preferences for fall detection were inconsistent across the studies. Their acceptance was diminished primarily by the high rate of false alarms; some found them uncomfortable to wear, and some raised issues such as stigmatization. Some studies showed a lower preference for fall detectors than security-enhancing sensors. 40,41 In another study, some participants thought that they were not old enough to need such tools. 42 However, in studies where the main focus was fall detection, it was concluded that users valued the fall detection feature. 23,32
Improving the specificity of wearable fall detectors is problematic because to subject-to-subject and instance-to-instance dependency of the fall events. Furthermore, although high detection accuracy can be achieved in the laboratory environment, performance decreases significantly in the actual environment. Moreover, falls are usually simulated by healthy volunteers, and there are many differences in gait or postural transition characteristics between the healthy and the elderly. Likewise, unsupervised or personalized testing and training of fall detectors using machine learning methods are difficult to perform because of the rarity of fall events. 47 Retrospective analysis of data from large-scale deployment of such systems may provide a solution. Meanwhile, a solution for detecting serious falls would be to use a combination of ambient presence sensors (e.g., PIR motion sensors) and an alert button worn around the neck or on wrist. The long response time associated with presence sensors may be circumvented by the alert button on many occasions, and the presence sensors would detect instances when a user may be unable to raise the alert (or not wearing the device).
There were further problems with wireless devices being out-of range 23 and having short battery life. These undermined perceived reliability of the monitoring systems and hence user acceptance. The out-of-range problem can be solved by using wireless networks that support extension to coverage. Use of power-efficient designs and low-power sensors and sending processed data rather than raw data were among the solutions suggested to overcome short battery life.
Physiological data measurements
There are many studies in the literature that report on only physiological data but relatively few that monitor both physiological and ADL data. Although in this review we report nine studies that monitored both physiological and activity data, three of them only tested accuracy of their wearable multisensor devices that also measured a physiological parameter. 31,34,35 Four of them 32,33,38,39 monitored pulse rate and respiratory flow rate via the bed sensor. However, these were not used for clinical purposes; rather, they were designed for supporting presence and fall detection (absence from bed). The remaining two monitored multiple parameters of ADL and physiological data 36,37 : Biddiss et al. 36 used self-rated mobility, and Merilahti et al. 37 considered sleep/awake classification and step count as activity data. There remains a need for studies that assess the benefit of combined monitoring of activity and physiological data.
It is beneficial to monitor daily blood pressure, heart rate, and weight of the elderly, depending on disease. Saturation of peripheral O2 may also be measured for chronic obstructive pulmonary disease patients or blood glucose for a diabetic person. A physician will normally determine which physiological data are to be monitored. Long-term studies will reveal which physiological data are valuable to monitor continuously and at what frequency.
Self-rated symptoms
Self-rated symptoms have long been used for diagnosis, assessing the progress of an illness, or measuring the response to a treatment. They can also be used in telecare. For example, in Biddiss et al., 36 self-rated rated physical and psychological symptoms were found to be more indicative of the need for medical intervention than the physiological measures.
Symptoms relevant to general health can be monitored (e.g., swollen ankles, dizziness, cough, urine excretion, pain, sleep quality, etc.). However, their daily monitoring can be laborious. Instead, users should be encouraged to report any change in their status of well-being and health. Valuable symptoms to monitor and monitoring frequency will depend on the current health status of the subject and can be determined through interviews and/or questionnaires with carers, doctors, and research. However, eliciting symptom data can become burdensome over extended periods of time, and, where possible, alternative nonintrusive techniques are to be preferred.
Outcomes
Relating activity data to physiological data and well-being
Some studies related the ADL to well-being of the subjects or to psychological parameters. 21,25,26,28,29,32 –34,38 Findings show that changes in several ADL (e.g., bedroom and bathroom activities, in-bed restlessness, and nocturnal activities) provided important clues to the subjects' well-being. However, none of the studies provided a description or a model of their approach toward their decision process. Rather, they analyzed the data retrospectively to identify intervals over which the activity data were abnormal and then attempted to determine a reason for the change 32 –34 or observed the changes in ADL following a known change in health status or medication. 27,38
Almost all of the ADL telemonitoring studies have reported some benefits for care of the elderly. With such a significant percentage of the elderly having chronic disease (or comorbidities) or being under an increased risk of developing one, any telemonitoring intervention aiming to improve quality of care of the elderly should consider monitoring medication adherence and illness related physiological parameters.
Alarms
Detecting changes in an activity pattern or physiological parameters is important. There is no well-established method, and the area requires further research. For the former, the approach of detecting deviations from a statistical normal can be adopted. 25,26,29,30 A normal behavior pattern can be established based on sensor statistics over 10–15 days. If the sensor statistics are outside the normal (i.e., mean±2 SD or mean±3 SD,) an alarm can be raised. The cumulative number of complaints or worsening symptoms over a period (e.g., a week as in Biddiss et al. 36 ) can be used to predict the time of intervention. For monitoring blood pressure and glucose level, existing guidelines can be adopted, until a better method is found.
High rates of false alerts were a common problem, especially those related to falls. These were attributed to the noise and artifacts in the data due to body movements for wearable sensors or visitors for ambient sensors. Algorithms that can deal with noisy data and data fusion are anticipated as a solution to the problem. 29,31,34 Although many mentioned high false alert rates, only one study 36 provided sensitivity and specificity values for its prediction algorithms.
User perception
Three main determinants of user perception were user needs and concerns, familiarity of the user with the sensors/tools, and sensor characteristics. User needs and concerns included age, illness, comorbidities, and experience from previous adverse health/safety events. For example, correct detection of fall was appreciated by a person who felt helpless after a previous serious fall. 41 User needs will also determine which activities to monitor and how to monitor. For example, any technology targeting the elderly should be “elderly friendly” (i.e., have a minimal user interface, be very simple to use, and have large displays) or be completely passive (i.e., only ambient sensors) for people with dementia 30 as they are likely to forget any wearable sensors.
Concerns of elderly people, in descending order, were found to be security, safety, well-being, falls, and ownership of the data. 40 –42 These affected the perception of the monitoring systems/sensors or smart houses and sensors that they are willing to adopt. They wanted to adopt certain sensors, such as PIR, stove top temperature sensor, closed circuit TV at the front door, intruder alarm, flood detector, movement detectors, and door sensors. 22,32,40,41 Furthermore, system features such as detecting an emergency or having safety-enhancing features helped to overcome their initial reluctance to the idea of being monitored. 41
Initial reluctance toward monitoring technologies was also an issue. Reasons for this include privacy concerns, stigmatization, 43,47 unfamiliarity with the tools and technology, 37,43,44 and inconvenience or disturbance it may cause at home. 28,38,42
People, especially the elderly, tend to prefer tools with which they are familiar. For example, the elderly may prefer paper questionnaires to those answered via a Web site or mobile text message. 44 Likewise, familiar measurements (blood pressure, weight, and exercise) were thought to be the easiest and the most interesting ones. 37
There were clear indications that participants were against invasive tools (i.e., videocameras and microphones). 28,41 Even an event-driven Web camera to reduce false alarm rates was not accepted owing to privacy concerns. 41 However, approaches that would guarantee anonymity (e.g., background-subtracted silhouette imagery for monitoring in Skubic et al. 38 ) were found to be acceptable.
Sensor characteristics that affect user acceptance include comfort of wearable sensors, noninvasiveness, accuracy, reliability, ease of use, whether the sensors enhance the sense of security and well-being,
32,40,41
and whether they have emergency capabilities.
32,41
Preferred sensor characteristics are as follows: • Accuracy and reliability. High false alarm rates and clinically inaccurate sensor data undermine user acceptability.
31,41
• Easy to understand and use. It should be easy to restart if it goes wrong,
37
preferably with self-integration capability (into the system). • Comfortable to wear and use.
23,31,37
Uncomfortable devices may not be worn, even if the devices were for treatment (e.g., electrocardiography monitoring device in Bidargaddi and Sarela
34
). • Invisible to visitors (or easy to hide) if possible.
28,41
This is to avoid stigmatization, inconvenience, or disturbance at home.
28,38,42
• Lighter and smaller devices/sensors
41
• Nonintrusive if possible (i.e., no videocamera or microphone
28,41
) • With a memory to log the measurements in case they cannot be sent straight away
39
Acceptability by health professionals depends on whether the monitoring system improves the effectiveness of treatment or healthcare and whether it reduces their work load. They prefer a system that supports their decision process without increasing their work load, a system presenting clinically useful/relevant information rather than a vast amount of clinically irrelevant data. Moreover, any change in care management will introduce organizational challenges. Therefore, the benefits from the change should justify the effort of the change.
From the outcomes on user perception, recommendations on design and preferred characteristics of a system can be made. First, a long-term health monitoring system should be fully automated so as to minimize human interaction and hence human errors. For example, manual data entry and daily reporting can be found to be laborious. 37 Second, device interactions and recovery from faults should be as simple as possible. Third, the things that the elderly have to learn should be minimized as they prefer tools with which they are familiar. 23,37,44 Fourth, data/information feedback should be available for those interested (e.g., the young, 37 those who want to take control of their healthcare, 28 or those who want ownership of the data 38,41 ). Finally, data security should be implicit.
Recommendations for systems for use in large-scale telemonitoring can be made. First, a large-scale long-term deployment will require a system with decision support tools (i.e., a system with automatic reasoning and knowledge extraction features) in order to support healthcare professionals. Second, the system should be easily configurable according to the user needs (i.e., should enable pick and mix sensor combinations or enable custom configuration due to differences in user needs and in layouts of residences). Third, the system should be easily scalable and interoperable. Scalability requires lower cost, including equipment, installation, and operational and maintenance costs. Short battery life and out-of-range problems have to be dealt with. Finally, the system should be able to perform remote software upgrades and maintenance and monitor battery status of wireless devices.
Conclusions
This is the first review on whether monitoring ADL of elderly people is beneficial to their well-being and healthcare. Findings of some studies are encouraging. However, for more conclusive findings, there is a need for better-designed studies with larger sample size, longer follow-up durations, clinically relevant outcomes, and comparable outcome measures that are indicators of efficacy (effectiveness of care plan) and quality of the study. The studies should measure indicators of success of the new intervention, including participation rate (adherence statistics or drop out), sensitivity/specificity for any prediction tool, hospital visits, hospitalization rate, user satisfaction, and well-being of patients during follow-up (either periodically or at least at the baseline and end of the study). Studies should consider inclusion criteria of participants and ideally be based on severity of fraility, and outcomes should be correlated on objective metrics such as the Edmonton Frail Score. 56 It is important that common terminology is adopted, such as the International Classification of Functioning, Disability and Health of the World Health Organization, 57 to ensure comparability of studies.
Wearable technologies require much improvement in their accuracy and reliability and in particular the sensitivity and specificity of fall detectors and key event predictors, and these should be reported in outcomes.
Future studies should look to develop rule-based decision support tools that are based on combinations of activity information, physiological data, and self-rated symptoms. Important areas for further investigation include the following: • Determining correlation between changes in ADL, physiological parameters, and well-being/health status (i.e., extracting useful information relevant to subjects' well-being) • Determining relevance of activity data, physiological data, and self-rated symptoms for effectiveness of the intervention • Determining the most effective set of sensors
Development of these new approaches will take time, which may undermine the credibility of such systems at early stages of adoption. Legal issues (ethical, data security, and ownership of the data) and organizational challenges due to the changes in healthcare management may require consideration to enhance acceptance of such systems by users.
Footnotes
Disclosure Statement
No competing financial interests exist.
