Aortic valve rupture is a rare manifestation in comparison to cardiac rupture or contusion following blunt chest trauma. We report a case of aortic valve leaflet rupture with severe aortic regurgitation after a fall from a ladder. The aortic valve rupture had been missed in the emergency ultrasound and was only detected on comprehensive echocardiography after failure of weaning from a mechanical ventilator. The patient underwent aortic bioprosthetic valve replacement that dramatically changed the clinical course.
ParmleyLFManionWCMattinglyTW.
Nonpenetrating traumatic injury of the heart.Circulation1958;
18: 371–96.
3.
PrêtreRFaiduttiB.Surgical management of aortic valve injury after nonpenetrating trauma.Ann Thorac Surg1993;
56: 1426–1431.
4.
EgohYOkoshiTAnbeJAkasakaT.Surgical treatment of traumatic rupture of the normal aortic valve. Eur J Cardiothorac Surg1997;
11: 1180–1182.
5.
AndersonRG.Non-penetrating injuries of the heart.Br Med J1940;
2: 307–310.
6.
RichardsJRMcGahanJP.Focused assessment with sonography in trauma (FAST) in 2017: what radiologists can learn.Radiology2017;
283: 30–48.
7.
LiuJShenFTeboulJL, et al.
Cardiac dysfunction induced by weaning from mechanical ventilation: incidence, risk factors, and effects of fluid removal. Crit Care2016;
20: 69.