Loebe M , Hennig E , Müller J , Spiegelsberger S , Weng Y , Hetzer R.Long-term mechanical circulatory support as a bridge to transplantation, for recovery from cardiomyopathy, and for permanent replacement . Eur J Cardiothorac Surg1997; 11: S11-S24 .
2.
El-Banayosy A , Deng M , Loisance Det al.The European experience of Novacor left ventricular assist (LVAS) therapy as a bridge to transplant: a retrospective multi-centre study . Eur J Cardiothorac Surg1999; 15: 835-841 .
3.
Hunt SA , Frazier OH.Mechanical circulatory support and cardiac transplantation . Circulation1998; 97: 2079-2090 .
4.
Goldstein DJ , Oz MC , Rose EA.Implantable left ventricular assist devices . N Engl J Med1998; 339: 1522-1533 .
5.
Drews T , Loebe M , Ngo D-V , zu Dohna R , Weng Y , Hetzer R.Heart transplantation after mechanical circulatory support . Transplantationsmedizin1999; 4(Suppl.I): 179-179 .
6.
Schiessler A , Friedel N , Weng Y , Heinz U , Hummel M , Hetzer R.Mechanical circulatory support and heart transplantation. Pre-operative status and outcome . ASAIO J1994; 40: M476-M481 .
7.
Kormos RL , Borovetz HS , Gasior Tet al.Experience with univentricular support in mortally ill cardiac transplant candidates . Ann Thorac Surg49: 161-172 .
8.
Schmid C , Deng M , Hammel D , Weyand M , Loick HM , Scheld HH.Emergency versus elective/urgent left ventricular assist device implantation . J Heart Lung Transplant1998; 17: 1024-1028 .
9.
Loebe M , Müller J , Hetzer R.Ventricular assistance for recovery of cardiac failure . Curr Opin Cardiol1999; 14: 234-248 .
10.
Spencer FC , Eisman B , Trinkle JK , Rossi NP.Assisted circulation for cardiac failure following intracardiac surgery with cardiopulmonary bypass . J Thorac Cardiovasc Surg49: 56-73 .
11.
DeBakey ME.Left ventricular bypass pump for cardiac assistance . Am J Cardiol1971; 27: 3-11 .
12.
Noon GP , Lafuente JA , Irwin S.Acute and temporary ventricular support with BioMedicus centrifugal pump . Ann Thorac Surg1999; 68: 650-654 .
13.
Hausmann H , Potapov EV , Loebe Met al.Prognosis after implantation of an intraaortic balloon pump in cardiac surgery . Z Herz-, Thorax-, Gefäßchirurgie13: 249-254 .
14.
Korfer R , El-Banayosy A , Arusoglu Let al.Temporary pulsatile ventricular assist devices and biventricular assist devices . Ann Thorac Surg1999; 68: 678-683 .
15.
Pagani FD , Lynch W , Swaniker Fet al.Extracorporeal life support to left ventricular assist device bridge to heart transplant: a strategy to optimize survival and resource utilization . Circulation1999; 100(Suppl. 19): II206-II210 .
16.
Stiller B , Dahnert I , Weng YG , Hennig E , Hetzer R , Lange PE.Children may survive severe myocarditis with prolonged use of biventricular assist devices . Heart1999; 82: 237-240 .
17.
Martin J , Sarai K , Schindler M , van de Loo A , Yoshitake M , Beyersdorf F.MEDOS HIA-VAD biventricular assist device for bridge to recovery in fulminant myocarditis . Ann Thorac Surg1997; 63: 1145-1146 .
18.
Loebe MY , Weng J , Müller, Met al.Successful mechanical circulatory support for more than two years with a left ventricular assist device in a patient with dilated cardiomyopathyJ Heart Lung Transplant16: 1176-1179 .
19.
Hetzer R , Hennig E , Schiessler A , Friedel N , Warnecke H , Adt M.Mechanical circulatory support and heart transplantation . J Heart Lung Transplant11: 175-181 .
20.
Pasic M , Loebe M , Hummel Met al.Heart transplantation: a single center experience . Ann Thorac Surg62: 1685-1690 .
Hetzer R , Loebe M , Weng Y , Alexi-Meskishvili V , Lange PE.Mechanical circulatory support in children . Pediat Cardiac Surg Ann1999; 157-176 .
23.
Farrar DJ , Lawson JH , Litwak P , Cederwall G.Thoratec VAD system as a bridge to heart transplantation . J Heart Transplant1990; 9: 415-422 ; discussion 422-23.
24.
Guldner NW , Siemens HJ , Schramm Uet al.First clinical application of the Medos-HIA ventricular support system: monitoring of the thrombotic risk by means of the biomarker prothrombin fragment F1 + 2 and scanning electron microscopy evaluation . J Heart Lung Transplant1996; 15: 291-296 .
25.
DeVries WC.The permanent artificial heart. Four case reports . JAMA1988; 259: 849-859 .
26.
Arabia FA , Copeland JG , Smith RGet al.International experience with the CardioWest total artificial heart as a bridge to heart transplantation . Eur J Cardiothorac Surg1997; 11(Suppl.): S5-S10 .
27.
Pavie A , Leger P , Regan Met al.Clinical experience with a total artificial heart as a bridge for transplantation: the pitie experience . J Card Surg1995; 10: 552-558 .
28.
Nose Y , Nakata K , Yoshikawa Met al.Development of a totally implantable biventricular bypass centrifugal blood pump system . Ann Thorac Surg1999; 68: 775-779 .
29.
Potapov EV , Loebe M , Nasseri BAet al.Pulsatile flow in patients with novel nonpulsatile implantable LVAD . Circulation1999; 100: 166-166 .