Concerns about the potential impact of the non-pulsatile circulation pattern generated by the new generation axial-flow left ventricular assist devices on neurocognitive function led us to evaluate a patient in whom a Jarvik 2000 pump was implanted. We assessed the patient’s baseline neurocognitive function preoperatively as well as at 1-month and 6-month follow-up, using a comprehensive battery of neuropsychological tests. A slight improvement in circumscribed neurocognitive domains was noted, with no evidence of further decline at the end of a 6-month follow-up period.
Long JW, Healy AH, Rasmusson BY, et al. Improving outcomes with long-term "destination" therapy using left ventricular assist devices. J Thorac Cardiovasc Surg2008; 135: 1353-1354.
2.
Lazar RM, Shapiro PA, Jaski BE, et al. Neurological events during long-term mechanical circulatory support for heart failure. The randomized evaluation of mechanical assistance for the treatment of congestive heart failure (REMATCH) experience. Circulation2004; 109: 2423-2427.
3.
Frazier OHImplantation of the Jarvik 2000 left ventricular assist device without the use of cardiopulmonary bypass. Ann Thorac Surg2003; 75: 1028-1030.
Denault A., Deschamps A., Murkin JMA proposed algorithm for the intraoperative use of near-infrared spectroscopy . Semin Cardiothorac Vasc Anesth2007; 11: 274-282.
6.
Murkin JM, Newman SP, Stump DA, Blumenthal JAStatement of consensus on assessment of neurobehavioral outcomes after cardiac surgery. Ann Thorac Surg1995; 59: 1289-1295.
7.
Kosmidis MH, Vlahou CH, Panagiotaki P., Kiosseoglou G.The verbal fluency task in the Greek population: Normative data, and clustering and switching strategies. J Int Neuropsychol Soc2004; 10: 164-172.
8.
Zafiri M., Kosmidis MHEffects of demographic characteristics on the "Stroop conflict". Psychology2008; 15: 319-341.
9.
Slaughter MS , Sobieski MA, Gallacher C., et al. Low incidence of neurologic events during long-term support with the HeartMate XVE left ventricular assist device . Tex Heart Inst J2008; 35: 245-249.
10.
Westaby S., Siegenthaler M., Beyersdorf F., et al. Destination therapy with a rotary blood pump and novel power delivery. Eur J Cardiothor Surg2010; 37: 350-356.
11.
Anyanwu AC, Fischer GW, Plotkina I., Pinney S., Adams DHOff-pump implant of the Jarvik 2000 ventricular assist device through median sternotomy. Ann Thorac Surg2007; 84: 1405-1407.
12.
Anastasiadis K., Westaby S., Antonitsis P., et al. Minimal extracorporeal circulation circuit standby for "off-pump" left ventricular assist device implantation . Artificial Organs2010; doi:10.1111/j.1525-1594.2009.00983.x.
13.
Letsou GV, Myers TJ, Gregoric ID, et al. Continuous axial-flow left ventricular assist device (Jarvik 2000) maintains kidney and liver perfusion for up to 6 months. Ann Thorac Surg2003; 76: 1167-1170.
14.
Bornstein RA , Starling RC, Myerowitz PD, et al. Neurophychological function in patients with end-stage heart failure before and after cardiac transplantation. Acta Neurol Scand1995; 91: 260-265.
15.
Slater JP, Guarino T., Stack J., et al. Cerebral oxygen desaturation predicts cognitive decline and longer hospital stay after cardiac surgery. Ann Thorac Surg2009; 87: 36-45.
16.
Miller K., Myers TJ, Robertson K., et al. Quality of life in bridge-to-transplant patients with chronic heart failure after implantation of an axial flow ventricular assist device . Congest Heart Fail2004; 10: 226-229.
17.
Petrucci RJ , Wright S., Naka W. et al. Neurocognitive assessments in advanced heart failure patients receiving continuous-flow left ventricular assist devices . J Heart Lung Transplant2009; 28: 542-549.
18.
Zucalla G., Onder G., Pedone C., et al. Hypotension and cognitive impairment: selection association in patients with heart failure. Neurology2001; 57: 1986-1992.