The structural design sensitivity problem of a discrete mechanical system with a single viscous damper is considered. The sensitivity of the eigenvalues and the eigenvectors with respect to the damping parameter is evaluated. Exact analytical expressions for the eigenvalues and the eigenvectors of the modified system are obtained in addition to approximate expressions. A uniform n-mass oscillator viscously damped by a single damper is taken as an application example. Good agreement between the exact and approximate formulae is observed.
Get full access to this article
View all access options for this article.
References
1.
ZhangY.NguyenD. T.HouJ. W.‘An alternative formulation for design sensitivity analysis of linear structural dynamic systems, Computers & Structures, 44, 689–692 (1992).
2.
InmanD. J., Vibration, with Control Measurement and Stability, Prentice Hall International, Hemel Hempstead, 1989.
3.
HaftkaR. T.GürdalZ., Elements of Structural Optimization, 3rd edn, Kluwer Academic Publishers, Dordrecht, 1992.
4.
MüllerP. C., ‘Optimale Positionierung von Daempfern in Schwingungssystemen’, Zeitschr. Angew. Math. u. Mechanik, 68, T89–T90 (1988).
5.
GürgözeM.MüllerP. C., ‘Optimal positioning of dampers in multi-body systems, J. Sound Vibration, 158, 517–530 (1992).
6.
GürgózeM., ‘On some series occurring in the theory of vibrations, Int. J. Math. Educ. in Sci. and Technology, 23, 493–496 (1992).