The feasibility of using near infrared reflection spectroscopy for non-invasive blood glucose monitoring is discussed. Spectra were obtained using a diode-array spectrometer with a fiberoptic measuring head with a wavelength ranging from 800 nm to 1350 nm. Calibration was performed using partial least-squares regression and radial basis function networks. The results of different methods used to evaluate the quality of the recorded spectra in order to improve the reliability of the calibration models, are presented.
DeckertT., PoulsenJ.E., LarsenM.. Prognosis of diabetics with diabetes onset before the age of thirty-one.Diabetologia1978; 14: 363–70.
2.
ReichardP., Bengt-YngveN., RosenquistU.. The effect of long-term intensified insulin treatment on the development of microvascular complications of diabetes mellitus.N Engl J Med1993; 329: 304–9.
3.
The Diabetes Control and Complication Trial Research Group.The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus.N Engl J Med1993; 329: 977–86.
4.
BottU., JörgensV., GrüsserM., BenderR., MühlhauserI., BergerM.. Predictors of glycaemic control in type-1-diabetic patients after participation in an intensified treatment and teaching programme.Diabetic Med1993; 11: 326–71.
5.
PoitoutV., Moatti-SiratD., ReachG., ZangY., WilsonG.S., LemonnierF., KleinJ.C.. A glucose monitoring system for one line estimation in man of blood glucose concentrations using a miniaturized glucose sensor implanted in the subcutaneous tissue and a wearable control unit.Diabetologia1993; 36: 658–63.
6.
AaldersA.L., SchmidtF.J., SchoonenA.J.M., BroekI.R., MaessenAGFM, DoorenbosH.. Development of a wearable glucose sensor; studies in healthy volunteers and in diabetic patients.Int J Artif Organs1991; 14: 102–5.
7.
JanssonP.A., FowelinJ., SmithU., LönnrothP.. Characterization by microdialysis of intercellular glucose level in subcutaneous tissue in humans.Amer J Physiol1988; 88: E118–20.
8.
MeyerhoffC., BischofF., SternbergF., ZierH., PfeifferE.F.. On-line continuous monitoring of subcutaneous tissue glucose in men by combining portable glucosensor with microdialysis.Diabetologia1992; 35: 1087–92.
9.
KayashimaS., AriT., MikuchiM., SatoN.. Non-invasive transcutaneous approach to glucose monitoring.IEEE Trans (BME)1991; 38: 752–5.
10.
RaoG., Glikfeld, GuyR.H.. Reverse iontophoresis: development of a noninvasive approach for glucose monitoring.Pharm Res1993; 10: 1751–5.
11.
KajiwaraK., UemuraT., KishikawaH.. Noninvasive measurement of blood glucose concentrations by analysing Fourier transform infra-red absorbance spectra through oral mucosa.Med Biol Eng Comput1993; 31: S17–22.
12.
DuncanA., HanniganJ., FreebornS.S.. A portable noninvasive blood glucose monitor; Proc 8th International conference on solid-state sensors and actuators, and Eurosensors IX (Transducers 95, Eurosensors IX), Stockholm 25.06-29.06.95; 455-8.
13.
SpannerG., NiessnerR.. New concept for the non-invasive determination of physiological glucose concentrations using modulated laser diodes.Fresenius J Anal Chem1996; 3: 306–10.
14.
RobinsonM.R., EatonR.P., HaalandD.M., KoeppG.W., ThomasE.V.. Noninvasive glucose monitoring in diabetic patients: a preliminary evaluation.Clin Chem1992; 38: 1618–22.
15.
MarbachR.. Meßverfahren zur IR-spektroskopischen Blutglucosebestimmung, Fortschr-Ber.VDI Reihe8, Nr 346, Düsseldorf 1993.
16.
MarbachR., KoschinskyT., GriesF.A., HeiseH.M.. Noninvasive blood glucose assay by near-infrared diffuse reflectance spectroscopy of the human inner lip.Appl Spectrosc1993; 47: 875–81.
ScholzV., GrüsserM., BottU., JörgensV.. Behandlungs- und Schulungsprogramm für Typ-I-Diabetiker.Verlag Kirchheim, Mainz1992.
19.
HeinemannL.. Pharmakokinetik und Pharmakodynamik verschiedener Insulinpräparationen und Insulin-Analoga.Inauguraldissertation, Heinrich-Heine-Universität, Düsseldorf, Germany1993.
20.
MATLAB 4.3 for Windows.The Mathworks Inc, South Natick, MA.
21.
DemuthH., BealeM.. Neural network Toolbox 2 for use with Matlab, User's Guide.Nattick, MA: The Math Works, Inc.; 1994.
22.
HaalandD.M., ThomasE.V.. Partial least-squares methods for spectral analyses. 1. Relation to other quantitative calibration methods and the extraction of qualitative information.Anal Chem1988; 60: 1193–1202.
23.
ChenS., CowanC.F.N., GrantP.M.. Orthogonal least squares learning algorithm for radial basis function networks.IEEE Transaction Neural Networks1991; 2: 302–9.
24.
DerksEPPA, Sanchez PastorM.S., BuydensL.M.C.. Robustness analysis of radial base function and multi-layered feed-forward neural network models.Chemom Intell Lab Syst1995; 28: 49–60.
25.
OrrM.J.L.. Regularisation in the selection of radial basis function centres.Neural Computation1995; 7: 606–23.
26.
JagemannK.U., FischbacherC., DanzerK., MüllerU.A., MertesB.. Application of near-infrared spectroscopy for non invasive determination of blood/tissue glucose using neural networks.Z Phys Chem1995; 191: 179–90.
27.
StoneM.. Cross-validatory choice and assessment of statistical prediction.J Roy Stat Soc1974; 36(B): 111–33.
28.
ClarkeW.L., CoxD., Gonder-FrederickL.A., CarterW., PohlS.L.. Evaluating clinical accuracy of systems for self-monitoring, of blood glucose.Diabetes Care1987; 10: 622–8.
29.
RousseuwP.J.; Robust regression and outlier detection.Chichester: Wiley1987.