This paper describes a new material that is designed to reduce fire hazard by increasing the probability of escape from potential fire conditions. Specifically, The BFGoodrich Company includes an Early Warning Effect™ (EWE) system for poly (vinyl chloride) coated wallcovering. When heated to approximately 150°C, the wallcoverings release an odorless, colorless vapor that activates ionization smoke detectors prior to the development of smoke and flames. As such, the wallcoverings provide an "earlier warning" of a fire hazard compared to conventional interior furnishing materials.
Get full access to this article
View all access options for this article.
References
1.
Hillenbrand, L.J. and J.A. Wary.J. of Fire and Flammability/Consumer Product Flammability, 1:115 (1974).
2.
"Fire Tests in Ventilated Rooms: Detection of Cable-Tray and Exposure Fires," Report EP-NP-2751, prepared by Factory Mutual Research Corp., Inc. for the Electric Power Research Institute ( 1983).
3.
Silversides, R.G."Measurement and Control of Smoke in Building Fires," Symposium on Fire Test Methods-Restraint & Smoke 1966, Am. Soc. Testing Mat., 125 (1967 ).
4.
Hinderer, R.K.J. of Vinyl Technology , 7(1):2 (1985).
5.
Hofmann, H.T. and H. Sand.J. of Fire and Flammaility/Combustion Toxicology, 1:250 (1974).
6.
Harland, W.A. and W.D. Wooley."Fire Fatality Study,"University of Glasgow, Information Paper IP 18/79, Building Research Establishment (1979).
7.
Fire Safety Aspects of Polymeric Materials, 7, report prepared by the National Advisory Board, National Academy of Sciences, Lancaster, PA:Technomic Publishing Co., Inc., p. 30 (1979).
8.
Hilado, C.J. and H.J. Cumming.Fire and Materials , 2(2):68 (1978).
9.
Hilado, C.J. and P.A. Huttlinger.Fire Technology , 117 (1981).
10.
Kishitani, K. and K. Nakamura.J. of Fire and Flammability/Combustion Toxicology, 1:104 (1974).
11.
"Environments of Fire Detectors. Phase II Effect of Ceiling Configuration, 1, Report PB-290 951, prepared by Factory Mutual Research Corporation for the National Engineering Laboratory (1978).
12.
Fire Safety Aspects of Polymeric Materials, 7, report prepared by the National Advisory Board, National Academy of Sciences, Lancaster, PA:Technomic Publishing Co., Inc., p. 196 (1979).
13.
Meinhold, T.F.Plant Engineering, 62 (1977).
14.
National Bureau of Standards NBSIR 80-2077 , "Toxicity of the Products of Combustion."
15.
ASTM E 603-77, 1974Annual Book of ASTM Standards, 4.07, 574.
16.
NFPA 101, "Life Safety Code."
17.
NFPA 72E-1982, "Standard on Automatic Fire Detectors."
18.
Hilado, C.J.Flammability Handbook for Plastics, Lancaster, PA :Technomic Publishing Co., Inc., p. 34.
19.