To report the endovascular occlusion of an anastomotic false aneurysm of the ascending aorta.
Case Report:
A 51-year-old patient developed an anastomotic false aneurysm at the level of the aortic arch after surgical replacement of the aortic root and arch for aortic dissection. The aneurysm expanded after 6 months and because of its saccular shape was treated by selective occlusion with detachable microcoils. Magnetic resonance angiography showed the stability of the occlusion after 2 years.
Conclusions:
Endovascular treatment with coils may be a good alternative to surgery for saccular anastomotic false aneurysms.
BachetJTermignonJLGoudotB. Late reoperations in patients with aortic dissection. J Card Surg.1994;9:740–747.
2.
SakoHHadamaTMoriY. Factors affecting the occurrence of anastomotic leakage after graft replacement of type A aortic dissection [in Japanese]. Nippon Kyobu Geka Gakkai Zasshi. 1995;43:1736–1740.
3.
SullivanKLSteinerRMSmullensSN. Pseudoaneurysm of the ascending aorta following cardiac surgery. Chest. 1988;93:138–143.
4.
HazizaFMousseauxEGaidS. Spontaneous regression of a false aneurysm of the ascending aorta following surgery for dissection [in French]. J Radiol. 1999;80:153–156.
5.
YamashitaCTsujiYYoshimuraM. Successful surgical treatment of a pseudoaneurysm after composite graft replacement of the aortic valve and ascending aorta: report of two cases. Surg Today. 1994;24:1019–1022.
6.
OtakiM. Total composite graft replacement of the ascending aorta and aortic valve. J Med.1994;25:113–120.
7.
KatsumataTMoorjaniNVaccariG. Mediastinal false aneurysm after thoracic aortic surgery. Ann Thorac Surg.2000;70:547–552.
8.
MoriHFukudaTIshidaY. Embolization of a thoracic aortic aneurysm; the straddling coil technique: technical note. Cardiovasc Intervent Radiol. 1990;13:50–52.
9.
MiguelBCamilleriLGabrillarguesJ. Coil embolization of a false aneurysm with aorto-cutaneous fistula after prosthetic graft replacement of the ascending aorta. Eur J Radiol. 2000;34:57–59.
10.
RousseauHSoulaPPerreaultP. Delayed treatment of traumatic rupture of the thoracic aorta with endoluminal covered stent. Circulation. 1999;99:498–504.
11.
HenriquesJPBrutel de la RiviereASchepensMA. Percutaneous occlusion of the entry to a leaking false aneurysm after ascending aortic replacement for aortic dissection type A facilitating surgical repair. Eur J Cardiothorac Surg.1997;11:381–383.
12.
LempertTEHalbachVVHigashidaRT. Endovascular treatment of pseudoaneurysms with electrolytically detachable coils. AJNR Am J Neuroradiol. 1998;19:907–911.
13.
ChapotRHoudartESaint-MauriceJ. Endovascular treatment of cerebral mycotic aneurysms. Radiology. 2002;222:389–396.
14.
KawanabeYSadatoATakiW. Endovascular occlusion of intracranial aneurysms with Guglielmi detachable coils: correlation between coil packing density and coil compaction. Acta Neurochir (Wien). 2001;143:451–455.
15.
TurjmanFMassoudTFSayreJ. Predictors of aneurysmal occlusion in the period immediately after endovascular treatment with detachable coils: a multivariate analysis. AJNR Am J Neuroradiol. 1998;19:1645–1651.