This paper first describes the workflow of the Pathfinder image-guided surgical robot that has been designed to replace the stereotactic frame in neurosurgery, and then details the calibration stages employed in order to achieve submillimetre positioning accuracy of a tool tip. The process uses non-linear parameter identification techniques in conjunction with some procedures for camera calibration, which exploit the fact that the camera is mounted to a calibrated robot arm that executes precise motions.
AnC. H.AtkesonC. G.HollerbachJ. M.Model based control of a robot manipulator (MIT PressCambridge, MA1988)
9.
KhalilW.DombreE.Modeling, identification and control of robots (Kogan Page ScienceLondon2002)
10.
StrangG.Linear algebra and its applications, third edition (Saunders College PublishingFort Worth, TX1988)
11.
PressW. H.TeukolskyS. A.VetterlingW. T.FlanneryB. P.Numerical Recipes in C++, second edition (Cambridge University PressCambridge1992)
12.
LawsonC. L.HansonR. J.Solving least squares problems (Prentice-HallEnglewood Cliffs, NJ1974)
13.
KumarA.WaldronK. J.‘Numerical plotting of surfaces of positioning accuracy of manipulators.’Mechanism Mach. Theory16 (1981): 361–368
14.
HayatiS. A.‘Robot arm geometric link parameter estimation.’In Proceedings of 22nd IEEE Conference on Decision and control, San Antonio (1983): 1477–1483
15.
BeasleyR. A.HoweR. D.‘Increasing accuracy in image-guided robotic surgery through tip tracking and model-based flexion correction.’IEEE Trans. Robotics25 (2) (2009): 292–302
16.
ForsythD. A.PonceJ.Computer vision: a modern approach (Prentice-HallUpper Saddle River, NJ2003)
17.
TruccoE.VerriA.Introductory techniques for 3-D computer vision (Prentice HallUpper Saddle River, NJ1998)
TsaiR.‘A versatile camera calibration technique for high-accuracy 3D machine vision metrology using off-the-shelf TV cameras and lenses.’IEEE J. Robotics Automn RA-3 (4) (1987): 323–344
20.
ZhangZ.A flexible new technique for camera calibration Technical report MSR-TR-98–71, Microsoft Research, Redmond, WA, 1998.
21.
GruenA.HuangT. S. Ed. Calibration and orientation of cameras in computer vision (Springer-VerlagBerlin2001)
HartleyR.ZissermanA.Multiple view geometry in computer vision, second edition (Cambridge University PressCambridge2003)
27.
Longuet-HigginsH. C.‘A computer algorithm for reconstructing a scene from two projections.’Nature293 (1981): 133–135
28.
JosuttisN. M.The C++ standard library: a tutorial and reference (Addison Wesley, Hoboken, NJ1999)
29.
GoshtasbyA. A.2-D and 3-D image registration (Wiley, Hoboken, NJ2005)
30.
FitzpatrickJ. M.HillD. L. G.MaurerC. R.‘Image registration.’ In Handbook of medical imaging, Vol. 2: medical image processing and analysis (Eds SonkaM.FitzpatrickJ. M.), 2000, vol. PM80, ch. 8 (SPIE PressBellingham, WA).
31.
TriggsB.McLauchlanP.HartleyR.FitzgibbonA.‘Bundle adjustment — a modern synthesis.’In Proceedings of the International Workshop on Vision algorithms: theory and practice, Lecture Notes in Computer Science, vol. 1883 (2000): 298–372
32.
MorganP. S.CarterT.DavisS.SepehriA.PuntJ.ByrneP.MoodyA.FinlayP.‘The application accuracy of the Pathfinder neurosurgical robot.’In Proceedings of 17th International Congress on Computer assisted radiology and surgery, London (2003): 561–567
33.
EljamelM. S.‘Validation of the Pathfinder neurosurgical robot using a phantom.’Int. J. Med. Robotics Computer Assisted Surg.3 (2007): 372–377
34.
LiuJ.ZhangY.LiZ.‘Improving the positioning accuracy of a neurosurgical robot.’IEEE/ASME Trans. Mechatronics12 (5) (2007): 527–533
35.
LiQ. H.ZamoranoL.PandyaA.PerezR.GongJ.DiazF.‘The application accuracy of the NeuroMate robot — a quantitative comparison with frameless and frame-based surgical localization systems.’Computer Aided Surg.7 (2002): 90–98