In order to make the industrial testing and maintenance tasks for the tank floor safer, an automatic navigation magnetic flux leakage testing robot is designed. A fast multi circle detection method is presented for the testing robot with laser ranging location and differential driven technology. The calculation for the orientation deviation angle and the position of the robot is derived. The experimental results demonstrate that the proposed detection method and the incremental PID control algorithm perform the perfect tracking effect with high efficiency.
LiuZ., KangY., YangS. et al., Recent developments in magnetic flux leakage technology for petrochemical tank floor inspections, Materials Performance42(12) (2003), 24-27.
2.
BlakeleyB. et al., Above-ground storage tank inspection using the robot inspector, Insight47(11) (2005), 705-708.
3.
AmosD.M., The truth about magnetic flux leakage as applied to tank floor inspections, Insight38 (1996), 168-174.
4.
MasurahaV.K. and CarrS., Advanced above ground storage tank inspections-in-service robotics tank inspections, San Antonio: 2004 NPRA Environmental Conference (2004), 1-15.
5.
AtzlesbergeraJ. and ZagaraB., Magnetic flux leakage measurement setup for defect detection, Procedia Engineering5 (2010), 1401-1404.
6.
SongX., HuangS., ZhaoW. et al., Development of a high resolution MFL inspection system for tank floors, Control and Instruments in Chemical Industry34(1) (2007), 77-80.
7.