Abstract
The most common complication associated with immobilization is pressure sores caused by sustained localized tissue strain and stress. Computational simulations have provided insight into tissue stress-strain distribution, subject to loading conditions. In the simulation process, adequate soft tissue material parameters are indispensable. An in vivo procedure to characterise material parameters of human gluteal skin/fat and muscle tissue has been developed. It employs a magnetic resonance imaging (MRI) device together with an MRI compatible loading device. Using the derived data as constraints in an iterative optimization process the inverse finite element (FE) method was applied. FE-models were built and the material constants describing skin/fat and muscle tissue were parameterized and optimized. Separate parameter sets for human gluteal skin/fat and muscle were established. The long-term shear modulus for human gluteal skin/fat was