MelsenWG, RoversMM, GroenwoldRH, BergmansDC, CamusC, BauerT, et al. Attributable mortality of ventilator-associated pneumonia: a meta-analysis of individual patient data from randomised prevention studies. Lancet Infect Dis, 2013; 13(8):665–671.
2.
FeldmanC, KasselM, CantrellJ, KakaS, MorarR, Goolam MahomedA, PhilipsJ. The presence and sequence of endotracheal tube colonization in patients undergoing mechanical ventilation. Eur Respir J, 1999; 13(3):546–551.
3.
PavlinEG, VanNimweganD, HornbeinTF. Failure of a high-compliance low-pressure cuff to prevent aspiration. Anesthesiology, 1975; 42(2):216–219.
4.
CravenD. Prevention of hospital-acquired pneumonia: measuring effect in ounces, pounds, and tons. Ann Intern Med, 1995; 122(3):229–231.
5.
PneumatikosIA, DragoumanisCK, BourosDE. Ventilator-associated pneumonia or endotracheal tube-associated pneumonia? An approach to the pathogenesis and preventive strategies emphasizing the importance of endotracheal tube. Anesthesiology, 2009; 110(3):673–680.
6.
BalasEA, BorenSA. Managing clinical knowledge for health care improvement. Yearb Med Inform, 2000;(1):65–70.
7.
KlompasM, BerraL. Should ventilator-associated events become a quality indicator for ICUs?. Respir Care, 2016; 61(6):723–736.
8.
WyncollD, CamporotaL. Number needed to treat and cost-effectiveness in the prevention of ventilator-associated pneumonia. Crit Care, 2012; 16(3):430.
9.
YoungP, DoyleA. Preventing ventilator-associated pneumonia – the role of the endotracheal tube. Curr Respir Med Rev, 2012; 8:170–183.
10.
RezoagliE, CressoniM, BellaniG, GrasselliG, PesentiAM, KolobowT, et al. Prevention of lung bacterial colonization with a leak-proof endotracheal tube cuff: an experimental animal study. Respir Care, 2019; 64(9):1031–1041.
11.
ZanellaA, CressoniM, EppM, StylianouM, KolobowT. A double-layer tracheal tube cuff designed to prevent leakage: a bench-top study. Intensive Care Med, 2008; 34(6):1145–1149.
12.
PatelV, HodgesEJ, MariyaselvamMZ, PeuthererC, YoungPJ. Unintentional endotracheal tube cuff deflation during routine checks: a simulation study. Nurs Crit Care, 2019; 24(2):83–88.
13.
CaroffDA, LiL, MuscedereJ, KlompasM. Subglottic secretion drainage and objective outcomes: a systematic review and meta-analysis. Crit Care Med, 2016; 44(4):830–840.
14.
LorenteL, LecuonaM, JiménezA, LorenzoL, RocaI, CabreraJ, et al. Continuous endotracheal tube cuff pressure control system protects against ventilator-associated pneumonia. Crit Care, 2014; 18(2):R77.
15.
GopalS, LuckrazH, GiriR, NevillA, MuhammedI, ReidM, et al. Significant reduction in ventilator-associated pneumonia with the Venner-PneuX System in high-risk patients undergoing cardiac surgery: the Low Ventilator-Associated-Pneumonia study. Eur J Cardiothorac Surg, 2015; 47(3):e92–e96.
16.
DoyleA, FletcherA, CarterJ, BluntM, YoungP. The incidence of ventilator-associated pneumonia using the PneuX System with or without elective endotracheal tube exchange: a pilot study. BMC Res Notes, 2011; 4:92.