
Editorial
Select search scope: search across all journals or within the current journal










Radiologists work primarily in collaboration with other healthcare professionals. As such, these stakeholder perspectives are of value to the development and assessment of educational outcomes during the transition to competency-based medical education. Our aim in this study was to determine which aspects of the Royal College CanMEDS competencies for diagnostic radiology are considered most important by future referring physicians.
Institutional ethics approval was obtained. After pilot testing, an anonymous online survey was sent to all residents and clinical fellows at our university. Open-ended questions asked respondents to describe the aspects of radiologist service they felt were most important. Thematic analysis of the free-text responses was performed using a grounded theory approach. The resulting themes were mapped to the 2015 CanMEDS Key Competencies.
115 completed surveys were received from residents and fellows from essentially all specialties and years of training (out of 928 invited). Major themes were 1) timeliness and accessibility of service, 2) quality of reporting, and 3) acting as a valued team member. The competencies identified as important by resident physicians were largely consistent with the CanMEDS framework, although not all key competencies were covered in the responses.
This study illustrates how CanMEDS roles and competencies may be exemplified in a concrete and specialty-specific manner from the perspective of key stakeholders. Our survey results provide further insight into specific objectives for teaching and assessing these competencies in radiology residency training, with the ultimate goal of improving patient care through strengthened communication and working relationships.
Quantify resident caseload during call and determine if there are consistent differences in call volumes for individuals or resident subgroups.
Accession codes for after-hours computed tomography (CT) cases dictated by residents between July 1, 2012 and January 9, 2017 were reviewed. Case volumes by patient visits and body regions scanned were determined and categorized according to time period, year, and individual resident. Mean shift Relative Value Units (RVUs) were calculated by year. Descriptive statistics, linear mixed modeling, and linear regression determined mean values, differences between residents, associations between independent variables and outcomes, and changes over time. Consistent differences between residents were assessed as a measure of good or bad luck / karma on call.
During this time there were 23,032 patients and 30,766 anatomic regions scanned during 1,652 call shifts among 32 residents. Over the whole period, there were on average 10.6 patients and 14.3 body regions scanned on weekday shifts and 22.3 patients and 29.4 body regions scanned during weekend shifts. Annually, the mean number of patients, body regions, and RVUs scanned per shift increased by an average of 0.2 (1%), 0.4 (2%), and 1.2 (5%) (all p < 0.05) respectively in regression models. There was variability in call experiences, but only 1 resident had a disproportionate number of higher volume calls and fewer lower volume shifts than expected.
Annual increases in scan volumes were modest. Although residents’ experiences varied, little of this was attributable to consistent personal differences, including luck or call karma.
To examine if tweeting bias exists within imaging literature by determining if diagnostic test accuracy (DTA) studies with positive titles or conclusions are tweeted more than non-positive studies.
DTA studies published between October 2011 to April 2016 were included. Positivity of titles and conclusions were assessed independently and in duplicate, with disagreements resolved by consensus. A negative binomial regression analysis controlling for confounding variables was performed to assess the relationship between title or conclusion positivity and tweets an article received in the 100 days post-publication.
354 DTA studies were included. Twenty-four (7%) titles and 300 (85%) conclusions were positive (or positive with qualifier); 1 (0.3%) title and 23 (7%) conclusions were negative; and 329 (93%) titles and 26 (7%) conclusions were neutral. Studies with positive, negative, and neutral titles received a mean of 0.38, 0.00, and 0.45 tweets per study; while those with positive, negative, and neutral conclusions received a mean of 0.44, 0.61, and 0.38 tweets per study. Regression coefficients were -0.05 (SE 0.46) for positive relative to non-positive titles, and -0.09 (SE 0.31) for positive relative to non-positive conclusions. The positivity of the title (
The positivity of the title or conclusion for DTA studies does not influence the amount of tweets it receives suggesting that tweet bias is not present among imaging diagnostic accuracy studies. Study protocol available at https://osf.io/hdk2m/
The use of magnetic resonance imaging (MRI) during pregnancy is associated with concerns among patients and health professionals with regards to fetal safety. In this work, the Canadian Association of Radiologists (CAR) Working Group on MRI in Pregnancy presents recommendations for the use of MRI in pregnancy, derived from literature review as well as expert panel opinions and discussions. The working group, which consists of academic subspecialty radiologists and obstetrician-gynaecologists, aimed to provide updated, evidence-based recommendations addressing safety domains related to energy deposition, acoustic noise, and gadolinium-based contrast agent use based on magnetic field strength (1.5T and 3T) and trimester scanned, in addition to the effects of sedative use and occupational exposure.
To evaluate the interobserver agreement between radiologists using the Ultrasound Liver Reporting And Data System (US LI-RADS) visualization score and assess association between visualization score and cause of liver disease, sex, and body mass index (BMI).
This retrospective, single institution, cross-sectional study evaluated 237 consecutive hepatocellular carcinoma surveillance US examinations between March 4, 2017 and September 4, 2017. Five abdominal radiologists independently assigned a US LI-RADS visualization score (A, no or minimal limitations; B, moderate limitations; C, severe limitations). Interobserver agreement was assessed with a weighted Kappa statistic. Association between US visualization score (A vs B or C) and cause of liver disease, sex, and BMI (< or ≥ 25 kg/m2) was evaluated using univariate and multivariate analyses.
The average weighted Kappa statistic for all raters was 0.51. A score of either B or C was assigned by the majority of radiologists in 148/237 cases and was significantly associated with cause of liver disease (
Interobserver agreement between radiologists using US LI-RADS score was moderate. The majority of US examinations were scored as having moderate or severe limitations, and this was significantly associated with non-alcoholic steatohepatitis and increased BMI.
To discern whether preceding ultrasound (US) results, patient demographics and biochemical markers can be implemented as predictors of an abnormal Magnetic Resonance Cholangiopancreatography (MRCP) study in the context of acute pancreaticobiliary disease.
A retrospective study was performed assessing US results, age, gender, elevated lipase and biliary enzymes for consecutive patients who underwent an urgent MRCP following an initial US for acute pancreaticobiliary disease between January 2017-December 2018. Multivariable binary logistic regression models were constructed to assess for predictors of clinically significant MRCPs, and discrepant US/MRCP results.
A total of 155 patients (mean age 56, 111 females) were included. Age (OR 1.03,
An abnormal US, hyperlipasemia and increased age serve as predictors for a subsequent abnormal MRCP, as opposed to gender and biliary enzyme elevation. Age was the sole predictor of a significant US/MRCP discrepancy that provided new information which significantly impacted subsequent management. In the remaining cases, however, MRCP proved useful in reaffirming the clinical diagnosis and avoiding further investigations.
Assess quality metrics of modified barium swallow studies (MBSS) with and without a radiologist present during the procedure.
Retrospective review of MBSS performed on adult inpatients at a tertiary care hospital 6-months pre- and post-institutional change from having to not having a radiologist present during the examination.
fluoroscopy time; study duration; number of cine loops; number of images; efficiency of collimation (using a 5-point scoring system); time to final report; radiologist-speech language pathologist report disagreement; and recalls for inadequate studies. Statistical analysis was via Welch’s t-test and a test of proportions for continuous and count data under the normal approximation.
106 and 119 MBSS were analyzed from the radiologist present and radiologist absent periods, respectively. No statistically significant differences were found for: average fluoroscopy time (116.1 s vs. 126.9 s;
MBSS performed by technologists without radiologist supervision is not inferior to those performed with radiologist supervision on multiple performance measures. This supports technologist operated MBSS without radiologist supervision, while acknowledging a need to further address radiologist report time delay.
Regular screening mammography reduces breast cancer mortality. However, in women with dense breasts, the performance of screening mammography is reduced, which is reflected in higher interval cancer rates (ICR). In Canada, population-based screening mammography programs generally screen women biennially; however, some provinces and territories offer annual mammography for women with dense breast tissue routinely and/or on recommendation of the radiologist. This study compared the ICRs in those breast screening programs with a policy of annual vs. those with biennial screening for women with dense breasts. Among 148,575 women with dense breasts screened between 2008 to 2010, there were 288 invasive interval breast cancers; screening programs with policies offering annual screening for women with dense breasts had fewer interval cancers 63/70,814 (ICR 0.89/1000, 95% CI: 0.67-1.11) compared with those with policies of usual biennial screening 225/77,761 (ICR 1.45 /1000 (annualized), 95% CI: 1.19-1.72) i.e. 63% higher (p = 0.0016). In screening programs where radiologists’ screening recommendations were able to be analyzed, a total of 76,103 women were screened, with 87 interval cancers; the ICR was lower for recommended annual (65/69,650, ICR 0.93/1000, 95% CI: 0.71, 1.16) versus recommended biennial screening (22/6,453, ICR 1.70/1000 (annualized), 95%CI: 0.70, 2.71)(p = 0.0605). Screening program policies of annual as compared with biennial screening in women with dense breasts had the greatest impact on reducing interval cancer rates. We review our results in the context of current dense breast notification in Canada.
We evaluated the contribution to cancer detection of supplemental breast ultrasound screening in women with dense breasts based on a single center experience by comparing our results with similar programs elsewhere.
We performed a retrospective review of handheld sonographer-performed screening ultrasound exams at our academic breast imaging center, from January 1st to December 31st, 2019. Breast density, breast cancer risk factors, BI-RADS assessment, and lesion pathology were reviewed and tallied, followed by derivation of the biopsy rate, breast cancer detection rate, PPV3 and average tumor size. These values were compared to published results of breast screening programs elsewhere.
695 screening breast ultrasounds for women with dense breasts and negative mammograms were performed in 2019. The biopsy rate was 1.3%, breast cancer detection rate was 7 in 1000, PPV3 was 42%, and the average tumor size was 9.0 ± 1.4 mm.
The first-year data of the breast screening ultrasound program at our practice are promising, demonstrating comparable cancer detection rate, higher PPV3, and similar biopsy rate in those with dense breasts compared with similar programs elsewhere. Longitudinal analysis and larger sample size are required for validation. Comparison of incidence and prevalence screening data is also warranted to elucidate the true value of this program.
Digital breast tomosynthesis (DBT) is gradually being implemented in routine clinical breast imaging practice. The technique of image acquisition reduces the confounding effect of overlapping breast tissue, which substantially affects cancer detection, abnormal recall, and interval cancer rates in a screening/ surveillance setting. In a diagnostic setting, tomosynthesis also allows for improved lesion localization and characterization over conventional imaging, which potentially improves the accuracy and improved workflow efficiency. To optimize the utility of tomosynthesis, imagers should be aware of the pertinent aspects of image acquisition as it relates to interpretation, the appearance of benign and malignant pathologies, and sources of possible misinterpretation. This article aims to provide a practical knowledge base of DBT and demonstrate its potential benefits when incorporated into routine clinical practice.
The Covid pandemic has taught many lessons, including the importance of mental health. The value of the radiologist in holistic patient care may be underestimated and underresearched. Barriers to the acceptance of imaging as an important component in reassurance may be rooted in old ideas minimizing the importance of mental health.
Several articles in the literature have demonstrated a promising role for breast MRI techniques that are more economic in total exam time than others when used as supplement to mammography for detection and diagnosis of breast cancer. There are many technical factors that must be considered in the shortened breast MRI protocols to cut down time of standard ones, including using optimal fat suppression, gadolinium-chelates intravascular contrast administrations for dynamic imaging with post processing subtractions and maximum intensity projections (MIP) high spatial and temporal resolution among others. Multiparametric breast MRI that includes both gadolinium-dependent, i.e., dynamic contrast-enhanced (DCE-MRI) and gadolinium-free techniques, i.e., diffusion-weighted/diffusion-tensor magnetic resonance imaging (DWI/DTI) are shown by several investigators that can provide extremely high sensitivity and specificity for detection of breast cancer. This article provides an overview of the proven indications for breast MRI including breast cancer screening for higher than average risk, determining chemotherapy induced tumor response, detecting residual tumor after incomplete surgical excision, detecting occult cancer in patients presenting with axillary node metastasis, detecting residual tumor after incomplete breast cancer surgical excision, detecting cancer when results of conventional imaging are equivocal, as well patients suspicious of having breast implant rupture. Despite having the highest sensitivity for breast cancer detection, there are pitfalls, however, secondary to false positive and false negative contrast enhancement and contrast-free MRI techniques. Awareness of the strengths and limitations of different approaches to obtain state of the art MR images of the breast will facilitate the work-up of patients with suspicious breast lesions.
Contrast leakage after arthrography is common. We sought to investigate if immobilization could prevent it.
The purpose of this study was to determine the effects on contrast extravasation and image quality produced by strict immobilization of the shoulder between arthrography puncture and subsequent MR imaging.
Fifty patients underwent shoulder MR arthrography using a standard shoulder puncture in the anteroinferior quadrant. Ten milliliters of contrast mixture of saline, iodinated contrast, and gadolinium contrast was injected by a senior musculoskeletal (MSK) radiologist using a 21G needle. Half of the patients were immediately immobilized using a shoulder sling, and the other half were allowed to move their shoulder and arm freely during the time before MR imaging. MR arthrography was performed with a 3 T system using standard T1 and PD weighted sequences. The MR images were reviewed independently by 2 MSK radiologists and graded for extravasation using a five-point scale (1: none, 2: less than 2 cm, 3: 2-5 cm, 4: 5-10 cm, 5: more than 10 cm) and for image quality using a 5 point scale (1: poor, 5: good). The Pearson correlation was calculated to assess the correlation between leakage and image quality.
There was no significant difference in amount of leakage between both groups, and global image quality was found equal in both groups. A negative correlation was found between leakage and quality assessment.
This study shows that it cannot be avoided by strict shoulder immobilization and that it negatively affects image quality and interpretation.
The objective was to reconstruct the cervical neural foramen and accurately measure the minimum oblique sagittal area of the neural foramen. Then, a quantitative diagnostic standard for cervical neural foramen stenosis was proposed and its value as an indication for surgery was evaluated.
(1) CT data were used to reconstruct the neural foramen using Mimics software, and the minimum area was measured. (2) The optimal cut-off value was determined using a receiver operating characteristic (ROC) curve. (3) Patients who underwent single-segment surgery were divided into 2 groups according to the cut-off value. Then the postoperative neurological function improvement rate was analyzed to identify any significant difference between the 2 groups.
A total of 1056 neural foramens were measured in 132 patients, of which 495 (46.88%) were diagnosed as radiculopathy by clinical neurological examination. The optimal cut-off value determined by the ROC curve was 25.95 mm2 (sensitivity 74.1%, specificity 80.9%) and the area under the curve (AUC) was 0.827 (95%CI: 0.803-0.849). There was a significant difference in the neurological function improvement rate between the 2 groups after surgery (
Three-dimensional digital simulation reconstruction of CT data is a good measurement method. The optimal cut-off value determined here not only has a certain reference value for the diagnosis of cervical neural foramen bony stenosis, but also helps to select patients suitable for neural foramen decompression and can be used as a reference for surgical indication.
Coronavirus disease (COVID-19) has been associated with neurologic sequelae and neuroimaging abnormalities in several case series previously. In this study, the neuroimaging findings and clinical course of adult patients admitted with COVID-19 to a tertiary care hospital network in Canada were characterized.
This is a retrospective observational study conducted at a tertiary hospital network in Ontario, Canada. All adult patients with PCR-confirmed COVID-19 admitted from February 1, 2020 to July 22, 2020 who received neuroimaging related to their COVID-19 admission were included. CT and MR images were reviewed and categorized by fellowship-trained neuroradiologists. Demographic and clinical data were collected and correlated with imaging findings.
We identified 422 patients admitted with COVID-19 during the study period. 103 (24.4%) met the inclusion criteria and were included: 30 ICU patients (29.1%) and 73 non-ICU patients (70.9%). A total of 198 neuroimaging studies were performed: 177 CTs and 21 MRIs. 17 out of 103 imaged patients (16.8%) had acute abnormalities on neuroimaging: 10 had macrohemorrhages (58.8%), 9 had acute ischemia (52.9%), 4 had SWI abnormalities (23.5%), and 1 had asymmetric sulcal effacement suggesting possible focal encephalitis (5.8%). ICU patients were more likely to have positive neuroimaging findings, more specifically acute ischemia and macrohemorrhages (
Macrohemorrhages, acute ischemia and SWI abnormalities were the main neuroimaging abnormalities in our cohort of hospitalized COVID-19 patients. Acute ischemia and hemorrhage were associated with worse clinical status.
MRI is commonly used in follow up of high grade glioma. Our purpose is to assess the interrater agreement on the increasingly used visual qualitative assessment of various conventional and advanced MR techniques in the setting of treated high grade glioma in comparison to the well established quantitative measurements.
We prospectively enrolled HGG patients who underwent reresection of a new enhancing lesion on post-treatment 3T MR examination including DWI, DCE and DSC sequences. Two neuroradiologists objectively assessed the diffusion and perfusion maps by placing ROI on representative post-processed maps. They subjectively assessed the post-contrast, perfusion and diffusion sequences. Interrater agreement and concordance correlation coefficient were calculated.
Twenty-eight lesions were included. The interrater agreement on the qualitative assessment was good for k-trans (k = 0.73), moderate for Vp (k = 0.52), fair for AUC and Ve maps (k = 0.37 and 0.21), fair for corrected CBV (k = 0.39) and poor for the enhancement pattern and presence of diffusion restriction (k = 0.02 and 0.07). The concordance between the quantitative measurements was substantial for AUC and Vp (ρc = 0.98 and 0.97), moderate for k-trans and corrected CBV (ρc = 0.94) and poor for Ve and ADC (ρc = 0.86 and 0.24).
While the quantitative measurements of DSC and DCE perfusion maps show satisfactory inter-rater agreement, the qualitative assessment has lower interobserver agreement and should not be relied upon solely in the interpretation. Similarly, the suboptimal inter-rater agreement on the interpretation of enhancement pattern and diffusion restriction potentially limits their usefulness in differentiating glioma recurrence from treatment related changes.
Hemorrhagic transformation is caused by extravasation of blood products from vessels after acute ischemic stroke. It is an undesirable and potentially devastating complication, which occurs in 10%-40% of clinical cases. Hemorrhagic transformation is classified into four subtypes based on European cooperative acute stroke study II. Predicting hemorrhagic complications at presentation can be useful life saving/altering decisions for the patient. Also, understanding the mechanisms of hemorrhagic transformation can lead to new treatments and intervention measures. We highlighted various imaging techniques that have been used to predict hemorrhagic transformation. Specifically, we looked at the usefulness of perfusion and permeability imaging for hemorrhagic transformation. Use of imaging to predict hemorrhagic transformation could change patient management that may lead to the prevention of hemorrhagic transformation before it occurs. We concluded that the current evidence is not strong enough to rely on these imaging parameters for predicting hemorrhagic transformation and more studies are required.
Acute pulmonary embolism (APE) is a well-recognized cause of circulatory system compromise and even demise which can frequently present a diagnostic challenge for the physician. The diagnostic challenge is primarily due to the frequency of indeterminate presentations as well as several other conditions which can have a similar clinical presentation. This often obliges the physician to establish a firm diagnosis due to the potentially serious outcomes related to this disease. Computed tomography pulmonary angiography (CTPA) has increasingly cemented its role as the primary investigation tool in this clinical context and is widely accepted as the standard of care due to several desired attributes which include great accuracy, accessibility, rapid turn-around time and the ability to suggest an alternate diagnosis when APE is not the culprit. In Part 1 of this guidance document, a series of up-to-date recommendations are provided to the reader pertaining to CTPA protocol optimization (including scan range, radiation and intravenous contrast dose), safety measures including the departure from breast and gonadal shielding, population-specific scenarios (pregnancy and early post-partum) and consideration of alternate diagnostic techniques when clinically deemed appropriate.
The investigation of acute pulmonary embolism is a common task for radiologists in Canada. Technical image quality and reporting quality must be excellent; pulmonary embolism is a life-threatening disease that should not be missed but overdiagnosis and unnecessary treatment should be avoided. The most frequently performed imaging investigation, computed tomography pulmonary angiogram (CTPA), can be limited by poor pulmonary arterial opacification, technical artifacts and interpretative errors. Image quality can be affected by patient factors (such as body habitus, motion artifact and cardiac output), intravenous (IV) contrast protocols (including the timing, rate and volume of IV contrast administration) and common physics artifacts (including beam hardening). Mimics of acute pulmonary embolism can be seen in normal anatomic structures, disease in non-vascular structures and pulmonary artery filling defects not related to acute pulmonary emboli. Understanding these pitfalls can help mitigate error, improve diagnostic quality and optimize patient outcomes. Dual energy computed tomography holds promise to improve imaging diagnosis, particularly in clinical scenarios where routine CTPA may be problematic, including patients with impaired renal function and patients with altered cardiac anatomy.
An acute aortic syndrome (AAS) is an important life-threatening condition that requires early detection and management. Acute intramural hematoma (IMH), aortic dissection (AD) and penetrating atherosclerotic ulcer (PAU) are included in AAS. ADs can be classified using the well-known Stanford or DeBakey classification systems. However, these classification systems omit description of arch dissections, anatomic variants, and morphologic features that impact outcome. The Society for Vascular Surgery and Society of Thoracic Surgeons (SVS-STS) have recently introduced a classification system that classifies ADs according to the location of the entry tear (primary intimomedial tear, PIT) and the proximal and distal extent of involvement, but does not include description of all morphologic features that may have diagnostic and prognostic significance. This review describes these classification systems for ADs and other AAS entities as well as their limitations. Typical computed tomography angiography (CTA) imaging appearance and differentiating features of ADs, limited intimal tears (LITs), IMHs, intramural blood pools (IBPs), ulcer-like projections (ULPs), and PAUs will be discussed. Furthermore, this review highlights common imaging interpretation pitfalls, what should be included in a comprehensive CTA report, and provides a brief overview of current management options.
Intravenous [IV] esmolol, an alternative to IV metoprolol for coronary computed tomography angiography [CCTA], has shorter half-life that decreases the risk of prolonged hypotension. The primary aim was to prospectively compare IV esmolol alone to IV metoprolol alone for effectiveness in achieving heart rate [HR] of 60 beats per minute[bpm] during CCTA. The secondary aim was to compare hemodynamic response, image quality, radiation dose and cost.
Institutional Review Board approved prospective randomized study of 28 CCTA patients medicated in a 1:1 blinded match with IV esmolol or IV metoprolol to achieve HR of 60 bpm. Serial hemodynamic response was measured at 6 specified times. Two cardiac radiologists independently scored the image quality.
Both IV esmolol and IV metoprolol achieved the target HR. IV esmolol resulted in significantly less profound and shorter duration of reduction in systolic blood pressure [BP] than IV metoprolol with a difference of -10, -14 and -9 mm Hg compared to -20, -26 and -25 mmHg at 2, 15 & 30 min respectively. No significant difference in HR at image acquisition, exposure window, radiation dose and image quality. Although IV esmolol was expensive, the overall cost of care was comparable to IV metoprolol due to shortened post CCTA observation period consequent to faster restoration of hemodynamic status.
Comparison of IV esmolol and IV metoprolol demonstrate that both are effective in achieving the target HR but significantly faster recovery of HR and BP in patients who receive IV esmolol was found.
Assess the impact of 24/7/365 emergency trauma radiology (ETR) coverage on Emergency Department (ED) patient flow in an urban, quaternary-care teaching hospital.
Patient ED visit and imaging information were extracted from the hospital patient care information system for 2008 to 2018. An interrupted time-series approach with a comparison group was used to study the impact of 24/7/365 ETR on average monthly ED length of stay (ED-LOS) and Emergency Physician to disposition time (EP-DISP). Linear regression models were fit with abrupt and permanent interrupts for 24/7/365 ETR, a coefficient for comparison series and a SARIMA error term; subgroup analyses were performed by patient arrival time, imaging type and chief complaint.
During the study period, there were 949,029 ED visits and 739,796 diagnostic tests. Following implementation of 24/7/365 coverage, we found a significant decrease in EP-DISP time for patients requiring only radiographs (-29 min;95%CI:-52,-6) and a significant increase in EP-DISP time for major trauma patients (46 min;95%CI:13,79). No significant change in patient throughput was observed during evening hours for any patient subgroup. For overnight patients, there was a reduction in EP-DISP for patients with symptoms consistent with stroke (-78 min;95%CI:-131,-24) and for high acuity patients who required imaging (-33 min;95%CI:-57,-10). Changes in ED-LOS followed a similar pattern.
At our institution, 24/7/365 in-house ETR staff radiology coverage was associated with improved ED flow for patients requiring only radiographs and for overnight stroke and high acuity patients. Major trauma patients spent more time in the ED, perhaps reflecting the required multidisciplinary management.
The purpose of this article is to review the embryology of the lower limb arterial anatomy along with common variants and their clinical relevance.
Embryologic variations of the lower limb arterial system may be explained by i.) persistence of primordial arterial segments, ii.) abnormal fusion, iii.) segmental hypoplasia/absence, or a combination of both. Persistent sciatic artery, corona mortis, and popliteal entrapment syndrome will also be discussed with associated symptoms, and potential complications.
Knowledge of these variations is essential for surgical and endovascular management as failure to recognize them can result in complications.





