
Research article
Select search scope: search across all journals or within the current journal

Operative vaginal delivery has been described since the Middle Ages. During this time, however, labour would be sustained over several days and intrapartum death almost inevitable. In these circumstances, intervention involving the use of surgical instruments or even kitchen utensils would serve purely as an attempt to avoid maternal mortality. The establishment of forceps-assisted delivery as a means of avoiding both maternal and neonatal morbidity was initiated in the 16th century by the Chamberlen family and later developed over several centuries by leading obstetricians of the time including Simpson, Barnes and Keilland. The evolution of forceps is a fascinating story which is rich in history. Despite the development of Ventouse and the increasing use of Caesarean section for difficult delivery, forceps remain an integral part of obstetric practice. The striking resemblance of modern day forceps to the original instruments used by the Chamberlens is a testament to both the family's ingenuity and enterprise as well as the subsequent pioneering obstetricians who followed in their footsteps.
To characterize paediatric presentations of stabbing to emergency departments across London and to audit existing referral rates to the police and social services against the new standard set by the General Medical Council.
Retrospective multi-centre service evaluation/audit.
All emergency departments within London.
Patients under 18 years of age presenting to emergency departments with non-accidental stabbing between 1 April 2007 and 30 April 2009.
Patient age, nature of assault, assailant, injuries and management. Rates of documented referral to police and social services, as mandated by GMC guidance.
A total of 381 presentations were identified from 20 out of the 32 hospitals in London, 160 of whom were less than 16 years old. The majority were seen only by emergency department staff and only a minority (28%) were admitted. Three died in the departments. A knife was the commonest weapon and the limbs the most common site of injury. Referrals to police were documented in only 30% of patients (43% if <16 years old) and to social services in 16% (31% if <16 years old) of those discharged. In the majority, there was no documentation (police 64%, social services 79%).
A significant number of paediatric stabbings present to emergency departments across London. The majority of these are discharged directly from departments. Of those discharged, documentation regarding referral rates to Police and Social Services was poor, and documented referral rates low. This study covered a period prior to the introduction of new General Medical Council guidance and a repeat audit to assess subsequent documented referrals is required.
Skin lesions are extremely common, with 54% of the UK population being affected by skin disease annually. As such, dermatological conditions can be brought to light following admission to hospital for different underlying conditions, with 57% of the dermatological diagnoses made on the hospital wards, unrelated to previous patient history or reasons for admission. The role of the dermatologist is therefore comprehensive and inherently important in the hospital. General practitioners play an integral role in managing skin conditions in the community, with up to 24% of consultations relating to skin disease, referring patients to dermatology mainly for the management of more complex conditions, and diagnosis of certain skin lesions. It is therefore essential to further analyse these roles and to better understand the extent of inpatient and outpatient activity to better plan the provision of dermatological services whether in the community, or in the hospital.
Often considered no more than an historical curiosity, writer’s cramp remains an important disability in the workplace and the mechanism, which has puzzled the best medical minds for generations, remains contentious. A remarkable range of hypotheses has been put forward to try and explain a disability which periodically reached epidemic and economically worrying levels, but in the end medical opinion has accepted the explanation put forward by neurologists Sheehy and Marsden in 1983 that this was caused by a form of focal dystonia. However, the majority of the historical descriptions of writer’s cramp do not fit the classical parameters of focal dystonia and are more accurately described as a progressive forearm muscle fatigue. Today’s keyboard operators continue to complain of symptoms identical to their clerical forebears demonstrating that this is a problem which has evolved but not disappeared; this has the paradoxical advantage that modern research techniques enable this complaint to be revisited. The result shows that two varieties of writer’s cramp have always existed and while focal dystonia remains a valid explanation for a minority of cases, the much more common fatigue-based complaint is better explained by chronic compartment syndrome of the forearm.
A standardised terminology for describing medical devices can enable safe and unambiguous exchange of information. Proposed changes to EU-wide medical devices regulations mandate the use of such a system. This article reviews two important classification systems for medical devices in the UK. The Global Medical Device Nomenclature (GMDN) provides a classification system specifically for medical devices and diagnostics, and facilitates data exchange between manufacturers and regulators. SNOMED CT is the terminology of choice in the NHS for communicating, sharing and storing information about patients’ healthcare episodes. Harmonisation of GMDN and SNOMED CT will encourage use of single terminology throughout the lifetime of a device; from regulatory approval through clinical use and post-marketing surveillance. Manufacturers will be required to register medical devices with a European device database (Eudamed) and to fit certain devices with a Unique Device Identifier; both are efforts to improve transparency and traceability of medical devices. Successful implementation of these elements depends on having a consistent nomenclature for medical devices.
