
Research article
Select search scope: search across all journals or within the current journal

To evaluate the contrast enhanced ultrasound (CEUS) and contrast enhanced magnetic resonance imaging (CEMRI) features of intrahepatic splenosis (IHS).
Five patients (three males and two females, median age, 44 years; range,32–73 years) with seven IHSs were retrieved from the database of our hospital from March 2012 to October 2021. All IHSs were confirmed histologically by surgery. The CEUS and CEMRI characteristics of individual lesion were fully analyzed.
All IHS patients were asymptomatic and four out of five patients had history of splenectomy. On CEUS, all IHSs were hyperenhancement in arterial phase. 71.4% (5/7) of IHSs manifested overall filling within few seconds, the other two lesions showed centripetal filling. Subcapsular vascular hyperenhancement and feeding artery was seen in 28.6% (2/7) and 42.9% (3/7) of IHSs, respectively. During portal venous phase, IHSs presented hyperenhancement (2/7) or isoenhancement (5/7). Moreover, rim-like hypoenhanced area was uniquely observed surrounding 85.7% (6/7) of IHSs. In late phase, seven IHSs remained continuous hyper- or isoenhancement. On CEMRI, five IHSs showed mosaic hyperintense in early arterial phase, the other two lesions showed homogeneous hyperintense. In portal venous phase, all IHSs revealed continuous hyper- (71.4%, 5/7) or iso-intense (28.6%, 2/7). During late phase, one IHS (14.3%, 1/7) became hypointense, the other lesions remained hyper- or isointense.
Diagnosis of IHS can be based on typical CEUS and CEMRI features in patients with history of splenectomy.
The aim in this study was to determine the efficacy of shear wave dispersion (SWD) technique for the prediction of post hepatectomy liver failure (PHLF) in patients with hepatocellular carcinoma after hepatectomy and develop an SWD based risk prediction model.
We prospectively enrolled 205 consecutive patients who were scheduled to undergo hepatectomy for hepatocellular carcinoma (HCC), pre-operative SWD examination, laboratory data and some other clinicopathological tests were collected. The risk factors of PHLF were identified according to univariate and multivariate analysis, a predictive model was established based on logistic regression analyses.
SWD examination was successfully performed in 205 patients. PHLF occurred in 51 patients (24.9%), including 37/11/3 patients with Grade A/B/C, respectively. There was a high correlation between SWD value of liver and liver fibrosis stage (
SWD is a promising and reliable method for PHLF prediction in patients with HCC who were undergoing hepatectomy. Compared with SWD, Forns, APRI and FIB-4, PM demonstrate better efficacy for preoperative PHLF prediction.

To compare the diagnostic value of microvascular flow imaging (MVFI) with that of contrast-enhanced ultrasound (CEUS) for the analysis of blood flow in benign and malignant cervical lymph nodes.
As a prospective study, 95 cervical enlarged lymph nodes (43 benign and 52 malignant) were observed in 95 patients using conventional ultrasonography (including gray and Color Doppler Flow Imaging), CEUS, and MVFI. Two researchers evaluated vascular parameters of MVFI (vascular distribution, internal vascular features, vascular index) and CEUS (enhancement mode, enhancement type) and compared the diagnostic effects of MVFI and CEUS.All results were compared with pathological findings.
There were significant differences in the vascular distribution and internal vascular features of benign and malignant lymph nodes on MVFI (
Both CEUS and MVFI are valuable in differentiating benign and malignant lesions of lymph nodes and have a similar diagnostic performance; however, MVFI is less invasive and simpler than CEUS. Therefore it is preferred for auxiliary examination of enlarged lymph nodes that are difficult to diagnose by conventional ultrasound.
To present a method combining ultrasound (US) and contrast-enhanced ultrasound (CEUS) features for differential diagnosis of cervical tuberculous lymphadenitis (CTL) and primary lymphoma.
A total of 155 patients with CTL (
The combined model outperformed US model and CEUS model in distinguish CTL from lymphoma achieved favorable performances in training set and validation set with AUCs of 0.958 and 0.946 as well as high accuracies (91.7% and 87.2%), sensitivities (95.9% and 84.4%) and specificities (82.4% and 93.3%). Delong’s test showed that among the three models, combined model was significantly different from the other two models in training set (
A combination of US and CEUS achieved good diagnostic performance in differentiating lymphoma and CTL, which might aid in clinical decision-making.
Reconstructive surgery is established as a standard treatment option after mastectomy due to cancer. It is crucial to patients to achieve a natural and symmetric looking breast through reconstruction. Anthropometric measurements are used to assess the objective symmetry of the breast, which are prone to errors and difficult to reproduce.
The aim of this work is to validate breast volumetry using three-dimensional surface imaging.
We compared preoperatively analog and digitally evaluated volume of the breast with our gold standard, direct water displacement measurement of the mastectomy specimen. We examined 34 breast specimens in total.
Each measurement method (Breast Sculptor, VAM, Breast-V) for breast volume/mass determination demonstrates acceptable agreement ranges when compared with resected volumes and masses. The strongest volumetry instrument is Breast Sculptor (digital), the weakest is Breast-V (analog).
3D surface imaging is a quick, effective, and convenient method to evaluate breast shape and volume. The accuracy, reproducibility, and reliability of 3D surface imaging were comparable with MRI in our study.
This takes us a step closer to the long-term goal of establishing robust instruments to plan breast reconstructive surgery, achieve better surgical results, and contribute to quality assurance in breast surgery.
Iodinated contrast media (ICM) are widely used for diagnostic and interventional procedures in radiology and cardiology. Ideally, they should not interact with blood cells or vascular wall cells to avoid deteriorations of the blood circulation. However, it is well known that ICM can affect erythrocytes as well as endothelial cells which consequently might perturb especially the microcirculation. In former studies the influence of two ICM (iodixanol versus iopromide) on the vascular system, the development of blood stasis, on changes in renal resistive index (RRI) and vascular diameters, and on the post-mortem distribution of iodine as marker for ICM in the explanted kidneys was examined. The modus of ICM application into the supra-renal aorta followed the regime in interventional cardiology, so that 10 bolus injections were administered at steady intervals (iopromide 4,32 ml / iodixanol 5 ml) accompanied by infusion of 500 ml isotonic NaCl-solution.
In the present study, the post-mortem X-ray analysis revealed that there were no differences in iodine content in the regions of the mid-cortex and the medullo-pelvic transition zone of the kidneys after application of both ICM. Remarkable differences, however, were found in the region of the capsule-near cortex, where the application of iopromide led to a significantly lower iodine content in the microcirculation. This is in good agreement with former studies, in which a maldistribution in this area, presumably due to a decrease in arteriolar inflow as a result of stasis/occlusion was shown.
The study aim was to investigate the use of a novel device, the Vscan Air™, for rapidly and effectively performing ultrasound in student teaching during the COVID-19 pandemic.
As part of the ultrasound practical course with integrated hands-on activity required by the regular medical curriculum, 100 medical students were instructed in the use of the Vscan Air™, including duplex mode. They then evaluated the quality of the ultrasound images obtained by the Vscan Air™ from previously selected organs.
100 students were interviewed (female
The Vscan Air™ technology offered adequate image quality and provided a new, fast and patient-oriented technique to support continuous ultrasound examinations and education of students, especially during a pandemic. Particularly noteworthy is the uncomplicated compliance with the required high level of hygiene.
Recent studies have demonstrated that local application of corticosteroids reduces wound exudation following abdominoplasty and other reconstructive surgical procedures. On the other hand, corticosteroids might provoke wound healing disturbances due to their immunosuppressive effects.
The main objective of this study was to gain further information about the impact of the corticosteroid triamcinolone on cell migration in abdominoplasty patients.
An
There were no significant differences regarding cell migration when fibroblasts were incubated with triamcinolone + seroma containing culture medium compared to seroma containing culture medium without triamcinolone.
The performed
The cyanobacterium