Correction
Select search scope: search across all journals or within the current journal


After neoadjuvant chemotherapy (NAC), persistent microcalcifications are often observed in spite of a decrease in the primary tumor size.
To analyze the changes in microcalcifications after NAC and to evaluate the accuracy of residual microcalcifications in predicting the extent of residual cancer.
Eighty patients who received NAC and underwent both mammography and magnetic resonance imaging (MRI) before and after the completion of NAC were included. The location of microcalcifications was classified into two types: inside the mass and outside the mass.
The extent of the residual calcifications was larger than the pathologic residual lesion in 14 (74%) of 19 patients with complete response (CR) on MRI, but the discrepancy was <1 cm in eight (42%) patients. The median value of the discrepancy was significantly higher in patients showing CR with outside calcifications compared to CR with inside calcifications (2.0 cm vs. 0.7 cm,
The change in microcalcifications after NAC was correlated with the tumor response to NAC. The discrepancy was highest in the group showing CR on MRI with outside calcifications. In tumors with inside calcifications, the discrepancy was relatively low within an acceptable range.
The high requirements for mammography image quality necessitate a systematic quality assurance process. Digital imaging allows automation of the image quality analysis, which can potentially improve repeatability and objectivity compared to a visual evaluation made by the users.
To develop an automatic image quality analysis software for daily mammography quality control in a multi-unit imaging center.
An automated image quality analysis software using the discrete wavelet transform and multiresolution analysis was developed for the American College of Radiology accreditation phantom. The software was validated by analyzing 60 randomly selected phantom images from six mammography systems and 20 phantom images with different dose levels from one mammography system. The results were compared to a visual analysis made by four reviewers. Additionally, long-term image quality trends of a full-field digital mammography system and a computed radiography mammography system were investigated.
The automated software produced feature detection levels comparable to visual analysis. The agreement was good in the case of fibers, while the software detected somewhat more microcalcifications and characteristic masses. Long-term follow-up via a quality assurance web portal demonstrated the feasibility of using the software for monitoring the performance of mammography systems in a multi-unit imaging center.
Automated image quality analysis enables monitoring the performance of digital mammography systems in an efficient, centralized manner.

Advanced knowledge-based iterative model reconstructions (IMR) became recently available for routine computed tomography (CT). Using more realistic physical models it promises improved image quality and potential radiation dose reductions, both possibly beneficial for non-invasive assessment of coronary stents.
To evaluate the influence of different IMR settings at different radiation doses on stent lumen visualization in comparison to filtered back projection (FBP) and first-generation (hybrid) iterative reconstruction (HIR).
Ten coronary stents in a coronary phantom were examined at four different dose settings (120 kV/125 mAs, 120 kV/75 mAs, 100 kV/125 mAs, 100 kV/75 mAs). Images were reconstructed with stent-specific FBP and HIR kernels and with IMR using CardiacRoutine (CR) and CardiacSharp (CS) settings at three different iteration levels. Image quality was evaluated using established parameters: image noise; in-stent attenuation difference; and visible lumen diameter.
Image noise was significantly lower in IMR than in corresponding HIR and FBP images. At lower radiation doses, image noise increased significantly except with IMR CR3 and IMR CS3. Visible lumen diameters were significantly larger with IMR CS than with FBP, HIR, and IMR CR. IMR CR showed the smallest attenuation difference, while attenuation was artificially decreased extensively with IMR CS. FBP and HIR showed moderately increased in-stent attenuations. No relevant influence of used radiation doses on visible lumen diameters or attenuation differences was found.
IMR CR reduces image noise significantly while offering comparable stent-specific image quality in comparison to FBP and HIR and therefore potentially facilitates stent lumen delineation. Utilization of IMR CS for stent evaluation seems unfavorable due to artificial image alterations.
There is increased interest in pulmonary magnetic resonance imaging (MRI) as a radiation-free alternative to computed tomography (CT) for lung cancer screening.
To analyze MRI characteristics of pulmonary nodules with different non-enhanced sequences.
Eighty-two participants of a lung cancer screening were included. MRI datasets of 32 individuals with 46 different nodules ≥ 6 mm were prospectively evaluated together with 50 controls by two readers. Acquired sequences were T2- short tau inversion recovery (STIR), T2, balanced steady-state free precession (bSSFP), 3D-T1, and diffusion-weighted imaging (DWI). Each sequence was randomly and separately viewed blinded to low-dose CT (LDCT). Size, shape, and contrast of nodules were evaluated on each sequence and then correlated with LDCT and histopathology.
All eight carcinomas were detected by T2-STIR, T2, and bSSFP, and 7/8 by 3D-T1. Contrast was significantly higher for malignant nodules on all sequences. The highest contrast ratio between malignant and benign nodules was provided by T2-STIR. Of eight carcinomas, seven showed restricted diffusion. Size measurement correlated significantly between MRI and LDCT. Sensitivity/specificity for nodules ≥ 6 mm was 85–89%/92–94% for T2-STIR, 80–87%/93–96% for T2, 65–70%/96–98% for bSSFP, and 63–67%/96–100% for 3D-T1. Seven of eight subsolid nodules were visible on T2-sequences with significantly lower lesion contrast compared to solid nodules. Two of eight subsolid nodules were detected by bSFFP, none by 3D-T1. All three calcified nodules were detected by 3D-T1, one by bSSFP, and none by T2-sequences.
Malignant as well as calcified and subsolid nodules seem to have distinctive characteristics on different MRI sequences. T2-imaging was most suitable for the detection of nodules ≥ 6 mm.
Concern about radiation exposure is leading to an increasing interest in low-concentration contrast medium administration.
To evaluate the image quality and safety profile after administration of iodixanol 270 mg I/mL at 100-kVp tube voltage with iterative reconstruction in subjects undergoing computed tomography angiography (CTA).
Patients who completed CTA examination using iodixanol 270 mg I/mL and 100-kVp tube voltage along with iterative reconstruction for coronary, aortic, head and neck, renal, or pulmonary arteries were included. Image quality was qualitatively and quantitatively evaluated. Incidence of adverse events (AEs) and adverse drug reactions (ADRs) within seven days and radiation dose were also analyzed.
A total of 4513 individuals in 42 centers in China were enrolled, among which 4367 were included in efficacy analysis. The mean image quality score was 4.8 ± 0.45 across all arteries (all above 4.6) and 99.7% of the individuals’ images were classified as evaluable. The CT attenuation, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) in the regions of interest (ROIs) were 431.79 ± 99.018, 18.29 ± 11.947, and 28.21 ± 19.535 HU, respectively. Of all the participants, 68 (1.5%) and 65 (1.4%) experienced AEs and ADRs, respectively. No serious AEs or AEs leading to discontinuation occurred. The average effective radiation dose was 3.13 ± 2.550 mSv.
Iodixanol 270 mg I/mL in combination with 100-kVp tube voltage and iterative reconstruction could be safely applied in CTA and yield high-quality and evaluable images with reduced radiation dose.
The early and accurate detection of local or regional recurrence of head and neck tumor is critically important.
To compare the diagnostic accuracy of contrast-enhanced computed tomography (CT), contrast-enhanced magnetic resonance imaging (MRI), and fluorodeoxyglucose (FDG) positron emission tomography (PET)-CT, alone and in combination, in detecting the locoregional recurrence of malignant head and neck tumor.
A total of 93 patients with loco-regional recurrence of malignant head and neck tumors underwent CT, MRI, and PET-CT within 30 days before surgery. CT, MRI, and PET-CT for each patient were retrospectively reviewed to determine the presence of recurrent tumors in the primary site on a patient-by-patient basis and that of regional lymph nodes on a level-by-level basis. The diagnostic accuracy of CT, MRI, and PET-CT, alone and combined, were accessed with the postoperative histopathological findings or with 12-month follow-up results as the standard of reference.
The sensitivity/specificity/and accuracy of CT, MRI, and PET-CT for the detection of primary site recurrence was 89.9/85.7/89.3%, 94.9/85.7/93.6%, and 97.5/92.9/96.8%, respectively. The sensitivity/specificity/accuracy of CT, MRI, and PET-CT for the detection of nodal recurrence was 66.3/99.4/92.4%, 74.7/99.4/94.2%, and 85.5/94.9/93.0%, respectively. MRI + PET-CT achieved the best performance in the receiver operating characteristics curve analysis (Az value = 0.958 for primary site recurrence and 0.929 for nodal recurrence).
MRI + PET-CT offered the highest diagnostic performance in the detection of loco-regional recurrence of malignant head and neck tumor, compared with CT, MRI, PET-CT, and other combinations including CT.
Ossification of the nuchal ligament (ONL) caused by chronic injury to the nuchal ligament (NL) is very common in instability-related cervical disorders.
To determine possible correlations between ONL, sagittal alignment, and segmental stability of the cervical spine.
Seventy-three patients with cervical spondylotic myelopathy (CSM) and ONL (ONL group) and 118 patients with CSM only (control group) were recruited. Radiographic data included the characteristics of ONL, sagittal alignment and segmental stability, and ossification of the posterior longitudinal ligament (OPLL). We performed comparisons in terms of radiographic parameters between the ONL and control groups. The correlations between ONL size, cervical sagittal alignment, and segmental stability were analyzed. Multivariate logistic regression was used to identify the independent risk factors of the development of ONL.
C2–C7 sagittal vertical axis (SVA), T1 slope (T1S), T1S minus cervical lordosis (T1S-CL) on the lateral plain, angular displacement (AD), and horizontal displacement (HD) on the dynamic radiograph increased significantly in the ONL group compared with the control group. The size of ONL significantly correlated with C2–C7 SVA, T1S, AD, and HD. The incidence of ONL was higher in patients with OPLL and segmental instability. Cervical instability, sagittal malalignment, and OPLL were independent predictors of the development of ONL through multivariate analysis.
Patients with ONL are more likely to have abnormal sagittal alignment and instability of the cervical spine. Thus, increased awareness and appreciation of this often-overlooked radiographic finding is warranted during diagnosis and treatment of instability-related cervical pathologies and injuries.
The value of magnetic resonance imaging (MRI) signs in differentiating Ewing sarcoma from osteomyelitis has not be thoroughly investigated.
To investigate the value of various MRI signs in differentiating Ewing sarcoma from osteomyelitis.
Forty-one patients who underwent MRI because of a bone lesion of unknown nature with a differential diagnosis that included both Ewing sarcoma and osteomyelitis were included. Two observers assessed several MRI signs, including the transition zone of the bone lesion, the presence of a soft-tissue mass, intramedullary and extramedullary fat globules, and the penumbra sign.
Diagnostic accuracies for discriminating Ewing sarcoma from osteomyelitis were 82.4% and 79.4% for the presence of a soft-tissue mass, and 64.7% and 58.8% for a sharp transition zone of the bone lesion, for readers 1 and 2 respectively. Inter-observer agreement with regard to the presence of a soft-tissue mass and the transition zone of the bone lesion were moderate (κ = 0.470) and fair (κ = 0.307), respectively. Areas under the receiver operating characteristic curve of the diameter of the soft-tissue mass (if present) were 0.829 and 0.833, for readers 1 and 2 respectively. Mean inter-observer difference in soft-tissue mass diameter measurement ± limits of agreement was 35.0 ± 75.0 mm. Diagnostic accuracies of all other MRI signs were all < 50%.
Presence and size of a soft-tissue mass, and sharpness of the transition zone, are useful MRI signs to differentiate Ewing sarcoma from osteomyelitis, but inter-observer agreement is relatively low. Other MRI signs are of no value in this setting.
Conventional magnetic resonance imaging (MRI) is adversely affected by thick slices, small intersection gaps, and the partial volume effect, leading to the missed diagnosis or misdiagnosis of pituitary micro-lesions.
To evaluate the diagnostic yield of three-dimensional sampling perfection with application-optimized contrasts using different flip-angle evolutions (3D-T2 SPACE) sequences compared with a standard MRI protocol for the diagnosis of pituitary micro-lesions.
The MRI findings of 664 patients with clinically suspected pituitary lesions were retrospectively analyzed. All patients underwent coronal 3D-T2 SPACE sequences followed by T1-weighted (T1W) imaging. Conventional scanning sequences included coronal and sagittal T1W imaging and post-contrast enhanced coronal and sagittal T1 imaging. All images were independently evaluated by two experienced neuroradiologists. The inter-observer agreement was analyzed using kappa statistics.
Compared with conventional sequences, there was an increase in diagnostic confidence of 60.3% for the diagnosis of pituitary micro-lesions with the addition of 3D-T2 SPACE sequences. The lesion conspicuity scores of combined conventional and 3D-T2 SPACE sequences were significantly higher than those of conventional imaging (z = −6.403,
Combined with routine sequences, post-contrast enhanced 3D-T2 SPACE sequences effectively improve diagnostic confidence in the diagnosis of pituitary micro-lesions. Post-contrast enhanced 3D-T2 SPACE is suitable for detecting pico-adenomas, micro-lesions adjacent to the cavernous sinuses or sellar floor, lesions between the anterior and posterior lobes, and lesions with early phase enhancement.
The optimal optic nerve sheath diameter (ONSD) cut-off for identifying increased intracranial pressure (IICP) remains unclear in adult patients.
To validate the diagnostic accuracy of ultrasonographic (US) ONSD > 5.0 mm as a cut-off for detecting IICP by computed tomographic (CT) through a meta-analysis.
A systemic literature review was performed of online databases from January 1990 to September 2017. A bivariate random-effects model was used to estimate pooled sensitivity, specificity, and diagnostic odds ratio (DOR) with 95% confidence intervals (CIs). A summary receiver operating characteristic (SROC) graph was used to provide summary points for sensitivity and specificity. Meta-regression tests were performed to estimate the influence of the study characteristics on DOR. Publication bias was assessed using Deeks' funnel plot asymmetry test.
Six studies with 352 patients were included in the meta-analysis. US ONSD > 5.0 mm revealed pooled sensitivity of 99% (95% CI = 96–100) and specificity of 73% (95% CI = 65–80) for IICP detection. DOR was 178. The area under the SROC curve was 0.981, indicating a good level of accuracy. Meta-regression studies showed no significant associations between DOR and study characteristics such as probe mode (relative DOR [RDOR] = 0.60;
US ONSD > 5.0 mm can be used to rapidly detect IICP in adults in emergency departments and intensive care units. Further meta-analysis based on individual patient-level databases is needed to confirm these results.
Neuromelanin magnetic resonance imaging (NmMRI) and 123I-FP-CIT dopamine transporter single photon emission computed tomography (DAT-SPECT) provide specific information that distinguishes Parkinson's disease (PD) from non-degenerative parkinsonian syndrome (NDPS).
To determine whether a multiparametric scoring system (MSS) could improve accuracy compared to each parameter of DAT-SPECT and NmMRI in differentiating PD from NDPS.
A total of 49 patients, including 14 with NDPS, 30 with PD, and five with atypical parkinsonian disorder (APD) underwent both NmMRI and DAT-SPECT and were evaluated. The average (Ave) and the asymmetry index (AI) were calculated in the substantia nigra compacta area (SNc-area), SNc midbrain-tegmentum contrast ratio (SNc-CR), and specific binding ratio (SBR). Cut-off values were determined, using receiver operating characteristic (ROC) analysis, for the differentiation of PD from NDPS on the statistically significant parameters. All cases were scored as either 1 (PD) or 0 (NDPS) for each parameter according to its threshold. These individual scores were totaled for each case, yielding a combined score for each case to obtain a cut-off value for the MSS.
The Ave-SNc-area, Ave-SNc-CR, and Ave-SBR in PD were significantly lower than those in NDPS. The AI-SNc-area and AI-SBR in PD were significantly higher than those in NDPS. Of the five parameters, the highest accuracy was 93% for the Ave-SNc-area. For the MSS, a cut-off value of 3 was the accuracy of 96%. Besides, no significant difference was observed between PD and APD on all parameters.
An MSS has comparable or better accuracy compared to each parameter of DAT-SPECT and NmMRI in distinguishing PD from NDPS.
Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) has been used for assessing orbital lymphoproliferative disorders (OLPDs). However, only the mean values of quantitative parameters were obtained in previous studies and tumor heterogeneity was ignored.
To assess the value of DCE-MRI derived histogram parameters in differentiating malignant from benign OLPDs.
Forty-eight OLPDs patients (25 malignant and 23 benign) who had undergone DCE-MRI for pre-treatment evaluation were retrospectively included. Histogram parameters of
Tenth
Histogram analysis of DCE-MRI derived parameters may help to differentiate malignant from benign OLPDs. The 90th
Spontaneous subarachnoid hemorrhage (SAH) accounts for about 5% of strokes, but has a very high morbidity and mortality. Many survivors are left with important cognitive impairment and are severely incapacitated. Prediction of complications such as vasospasm and delayed cerebral ischemia, and of clinical outcome after SAH, is challenging. Imaging studies are essential in the initial evaluation of SAH patients and are increasingly relevant in assessing for complications and prognosis. In this article, we reviewed the role of imaging studies in evaluating early brain injury and predicting complications as well as clinical and neuropsychological prognosis after acute SAH.
Comparable oncological outcomes have been seen after surgical nephrectomy and thermal ablation of renal tumors recently. However, periprocedural outcome needs to be assessed for aiding treatment decision.
To compare efficacy rates and periprocedural outcome (technical success, session time, hospitalization time, and complications) after renal tumor treatment with laparoscopic partial nephrectomy (LPN) or radiofrequency ablation (RFA).
The initial experience with 49 (treated with LPN) and 84 (treated with RFA) consecutive patients for a single renal tumor (diameter ≤ 5 cm, limited to the kidney) during 2007–2014 was evaluated. Patient and tumor characteristics, efficacy rates, and periprocedural outcome were collected retrospectively. The stratified Mantel Haenzel and Van Elteren tests, adjusted for tumor complexity (with the modified R.E.N.A.L nephrometry score [m-RNS]), were used to assess differences in treatment outcomes.
Primary efficacy rate was 98% for LPN and 85.7% for RFA; secondary efficacy rate was 93.9% for LPN and 95.2% for RFA; and technical success rate was 87.8% for LPN and 100% for RFA. Median session (m-RNS adjusted
Both methods achieved equivalent secondary efficacy rates. RFA included several treatment sessions, but session and hospitalization times were shorter, and complications were less frequent than for LPN. The differences remained after adjustment for renal tumor complexity.